Maintenance
14. (Optional) The vortex plate should not normally
be removed unless the lower housing needs to
be cleaned. The vortex plate is secured with four
screws. If the vortex plate is removed, locate
the Vortex key and align with the cutout in the
housing to orient it properly in the housing
during reassembly.
5.1.1 Replacement Notes
The reassembly procedure is the reverse of the
disassembly with the notations below:
•
Thoroughly clean the interior of the filter housing, especially the sealing surfaces, O-ring groves and
O-rings.
•
When replacing the filter, position the seam in the filter membrane away from the water inlet.
•
Rotate the cleaning assembly clockwise while placing it over the filter. This reduces the bending of
the bristles sideways.
•
Before installing the filter adapter, clean the interface on the filter and apply a light coat of lubricant
to both O-rings to aid the assembly.
•
When closing the upper housing, make sure to lower it straight down over the alignment pins.
Make sure the main O-ring is seated properly in its groove.
•
Torque the mounting bolts to 80 lb-ft (108 N-m) in a crossing pattern.
•
Make sure to bleed the system before restarting.
Vortex Plate
Oval Cutout
Alignment Pin