1-74
S-104-100
Revised 09/2004
e-mail: [email protected]; [email protected]; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
LOOPERS AND SPREADERS
Travel of Looper to Center of Needle
The loopers must travel to the center part of the needle. To adjust, perform the following steps:
1. Loosen screw
A
and rotate core
B
clockwise or counterclockwise slightly (rotating the core clockwise
will move looper toward the needle; rotating the core counterclockwise will move the looper away from
the needle). Once the adjustment has been made, re-tighten screw
A
.
NOTE:
Make sure screw has been re-tightened before continuing on. If it has not been re-tightened, step
1
will have
to be repeated.
2. Turn the right hand stop wheel through both needle bar strokes, stopping after the needle bar has risen
.093” or 3/32” on both strokes. Check looper to needle to ensure adjustments are correct. If the travel of
the loopers is not to the center of the needle, repeat equalizations steps on pages 1-72 and 1-73, and repeat step
1 above.