1-61
S-104-100
Revised 09/2004
e-mail: [email protected]; [email protected]; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
CLAMPING
Setting the Spread of the Clamp Plates
The distance of the spread will be determined by the sewing application. The standard clearance between
the edge of clamp plate
A
and outstop
C
is 0.76 mm (.030”). To adjust, perform the following steps:
1. Turn the left hand crank so that the clamp rolls are not resting on the spreader block. Place the feeler
gauge between the edge of clamp plate
A
and outstop
C
. Slide the clamp plate towards the outstop until it
can no longer move. Holding the clamp plate against the feeler gauge using a screwdriver, slide instop
E
outward. Once the instop is over as far as it will go, tighten screw
D
. Once the clearance has been ob-
tained, remove the feeler gauge.
2. Repeat step 1 to obtain clearance between the other clamp plate and the outstop.