background image

11

10.0 

 A

vailable 

Ranges 

and 

Resolution 

by 

Engineering 

Unit

Engineering 

Unit

 

Factor

 

 

 

 

 

 

 

 

 

 

 

 

 

15 

 

30 

1  

100

 

300

 

500

 

1000

 

2000

 

3000

 

5000

 

10000

 

Burst Pressure

 

50

 

500

 

500

 

1000

 

2000

 

2000

 

10000

 

10000

 

10000

 

10000

 

15000

 

Proof Pressure

 

30

 

60

 

200

 

600

 

1000

 

2000

 

3000

 

6000

 

10000

 

15000

psi

 

 

1.0000

 

15.000

 

30.000

 

100.00

 

300.00

 

500.00

 

1000.0

 

2000.0

 

3000.0

 

5000.0

 

10000

bar

 

0.06894757

 

0.0689

 

1.0342

 

2.0684

 

6.8948

 

20.684

 

34.474

 

68.948

 

137.90

 

206.84

 

344.74

 

689.48

mbar

 

68.94757

 

68.948

 

1034.2

 

2068.4

 

6894.8

 

20684

 

34474

 

68948

 

*

kP

6.894757

 

6.8948

 

103.42

 

206.84

 

689.48

 

2068.4

 

3447.4

 

6894.8

 

13790

 

20684

 

34474

 

68948

Mpa

 

0.00689476

 

0.0069

 

0.1034

 

0.2068

 

0.6895

 

2.0684

 

3.4474

 

6.8948

 

13.790

 

20.684

 

34.474

 

68.948

kg/cm

2  

0.07030697

 

0.0703

 

1.0546

 

2.1092

 

7.0307

 

21.092

 

35.153

 

70.307

 

140.61

 

210.92

 

351.53

 

703.07

mmHg 

0°C

 

51.71508

 

51.715

 

775.73

 

1551.5

 

5171.5

 

15515

 

25858

 

51715

 

*

inHg 

0°C

 

2.03602

  

2.0360

 

30.540

 

61.081

 

203.60

 

610.81

 

1018.0

 

2036.0

 

4072.0

 

6108.1

 

10180

 

20360

cmH

2

4°C

 

70.3089

  

70.309

 

1054.6

 

2109.3

 

7030.9

 

21093

 

35154

 

70309

 

*

cmH

2

20°C

 

70.4336

  

70.434

 

1056.5

 

2113.0

 

7043.4

 

21130

 

35217

 

70434

 

*

mmH

2

4°C

 

703.089

  

703.09

 

10546

 

21093

 

70309

 

mmH

2

20°C

 

704.336

  

704.34

 

10565

 

21130

 

70434

 

*

mH

2

4°C

 

0.703089

 

0.7031

 

10.546

 

21.093

 

70.309

 

210.93

 

351.54

 

703.09

 

1406.2

 

2109.3

 

3515.4

 

7030.9

mH

2

20°C

 

0.704336

 

0.7043

 

10.565

 

21.130

 

70.434

 

211.30

 

352.17

 

704.34

 

1408.7

 

2113.0

 

3521.7

 

7043.4

inH

2

4°C

 

27.68067

 

27.681

 

415.21

 

830.42

 

2768.1

 

8304.2

 

13840

 

27681

 

55361

 

83042

 

*

inH

2

20°C

 

27.72977

 

27.730

 

415.95

 

831.89

 

2773.0

 

8318.9

 

13865

 

27730

 

55460

 

83189

 

*

inH

2

60°F

 

27.70759

 

27.708

 

415.61

 

831.23

 

2770.8

 

8312.3

 

13854

 

27708

 

55415

 

83123

 

*

Torr

 

51.71508

 

51.715

 

775.73

 

1551.5

 

5171.5

 

15515

 

25858

 

51715

 

*

 

1. Also applies to -15 to +30 PSI compound range.

 

 

2. 

 Cells noted with * will not be displayed due to limitations on display resolution. In all cases, resolution is limited to 100,0

00 counts.

Содержание JOFRA IPI Mk. II

Страница 1: ...User Manual Industrial Pressure Indicator AMETEK JOFRA IPI Mk II...

Страница 2: ...2 0 IPI Mk II Display and Controls 4 3 0 Operation 4 4 0 Supervisory Mode 6 5 0 Normal Operation 7 6 0 Changing the Batteries 8 7 0 Cleaning 8 8 0 Specifications 9 9 0 Service Center Calibration or Re...

Страница 3: ...rom IPI Mk II including export of run data to text comma separated values CSV and Excel files Clear logged data in IPI Mk II 1 1 Contacting Ametek Sales Service Offices AMETEK MCT North America Tel 1...

Страница 4: ...rtified by CSA as conforming to relevant Canadian and USA standards Conforms to relevant European Union directives Wheeled bin conforms to EC directive 2002 96 EC Hazard Location Information Approvals...

Страница 5: ...I Mk II is not intended for use with flammable substances and is intended for installation only in locations providing adequate protection against the entry of solid foreign objects or water capable o...

Страница 6: ...to display PSI By pressing the and ZERO and MAX MIN keys you can scroll forward and backwards through the 18 standard engineering units plus a one custom unit scale When the desired unit is displayed...

Страница 7: ...second Note that 10 sec provides the fastest response time 7 Set TARE This allows you to set a constant offset value which is then subtracted from the measured pressure For example if a TARE is set at...

Страница 8: ...adjustment enable disable Damping settings enable disable Sample rate setting enable disable Tare setting enable disable Custom engineering units set scale factor 4 Use the CONFIG key to scroll throug...

Страница 9: ...ng the MAX MIN button once will display the minimum pressure from memory Pressing the MAX MIN button again will display the maximum pressure from memory After about 2 seconds the gauge returns to norm...

Страница 10: ...se with the backlight off With intermittent use batteries could last a year or more There is a low battery icon in the upper left of the display It will appear when battery level is low Replace batter...

Страница 11: ...000 and 5 000 PSI 70 to 350 bar ranges 2X input pressure range 10 000 PSI 700 bar 1 5X input pressure range Overload Alarm indicate OL on display 1 2X input pressure range Temperature Compensation Fu...

Страница 12: ...rs at slow sample rate Low Battery Indicator icon is displayed near the end of battery life 9 0 Service Center Calibration or Repair Only qualified service personnel should perform calibration repairs...

Страница 13: ...1 5 15515 25858 51715 inHg 0 C 2 03602 2 0360 30 540 61 081 203 60 610 81 1018 0 2036 0 4072 0 6108 1 10180 20360 cmH 2 O 4 C 70 3089 70 309 1054 6 2109 3 7030 9 21093 35154 70309 cmH 2 O 20 C 70 4336...

Страница 14: ...LT Returns an error code from the error queue IDN Identification query Returns the manufacturer model number and firmware revision level of the Calibrator TARE Tares the offset pressure of the reading...

Страница 15: ...TEMP_UNIT Used to set temperature unit TEMP_UNIT Returns temperature unit Parameter Units Units Meaning Psi Pressure in pounds per square inch Bar Pressure in bars mBar Pressure in millibars Kg cm2 P...

Страница 16: ...e not connected 12 0 Warranty According to current terms of sale and delivery This warranty only covers defects in manufacture and becomes void if the instrument has been subject to unauthorised inter...

Страница 17: ..._ Temp Sensor Service request This instrument is sent for calibration input please tick off ___ Calibration as left ___ Check ___ Calibration as found and as left ___ Service ___ Accredited calibratio...

Страница 18: ......

Страница 19: ...SPK IPI 004 0200044 Rev A ATEX 10 12...

Страница 20: ...surement tasks from handheld field instruments to laboratory reference level bench top instruments JOFRA JF Marine Instruments A complete range of calibration equipment for temperature pressure and si...

Отзывы: