background image

1

1.0 Introduction

The IPI Mk. II combines the high accuracy of digital electronics with the 
convenience and ease of use of an analog test gauge.  Accurate to ± 0.05% 
FS, the IPI Mk. II can be used as a calibration reference, or in any 
application where high accuracy pressure measurement is required.
Many user configurable functions have been designed into the IPI Mk. II 
including sampling rate, TARE, damping, auto shut off, and min-max.  Once 
the gauge is configured, settings can be locked and password protected to 
prevent unauthorized changes to configuration.

Optional data logging software.

IPILOG Software extends the functions of the JOFRA IPI Mk.II.
The Software lets you:
• Set up data logging configuration in IPI Mk.II
•  Upload logged data from IPI Mk.II, including export of run data to text, 

comma separated values (CSV), and Excel files

• Clear logged data in IPI Mk.II

1.1 Contacting Ametek

Sales & Service Offices:
AMETEK MCT (North America) 

Tel: +1 (727) 536 7831 • [email protected]

AMETEK Singapore Pte. Ltd. (Singapore) 

Tel: +65 6 484 2388 • [email protected]

AMETEK Inc. Beijing Rep. Office (China) 

Tel: +86 10 8526 2111 • [email protected]

AMETEK GmbH (Germany) 

Tel: +49 2159 9136 510 • [email protected]

AMETEK Lloyd Instruments (UK) 

Tel: +44 (0)1243 833 370 • [email protected]

1.2 Standard Equipment

Check to see that your IPI Mk. II has arrived intact. Batteries are factory 
installed.  Save the packing materials at least until you have verified that 
there is no concealed damage.  

1.3 Safety information 

A Warning identifies conditions and actions that pose hazard(s) to the user; 
a Caution identifies conditions and actions that may damage the Calibrator 
or the equipment under test.

Содержание JOFRA IPI Mk. II

Страница 1: ...User Manual Industrial Pressure Indicator AMETEK JOFRA IPI Mk II...

Страница 2: ...2 0 IPI Mk II Display and Controls 4 3 0 Operation 4 4 0 Supervisory Mode 6 5 0 Normal Operation 7 6 0 Changing the Batteries 8 7 0 Cleaning 8 8 0 Specifications 9 9 0 Service Center Calibration or Re...

Страница 3: ...rom IPI Mk II including export of run data to text comma separated values CSV and Excel files Clear logged data in IPI Mk II 1 1 Contacting Ametek Sales Service Offices AMETEK MCT North America Tel 1...

Страница 4: ...rtified by CSA as conforming to relevant Canadian and USA standards Conforms to relevant European Union directives Wheeled bin conforms to EC directive 2002 96 EC Hazard Location Information Approvals...

Страница 5: ...I Mk II is not intended for use with flammable substances and is intended for installation only in locations providing adequate protection against the entry of solid foreign objects or water capable o...

Страница 6: ...to display PSI By pressing the and ZERO and MAX MIN keys you can scroll forward and backwards through the 18 standard engineering units plus a one custom unit scale When the desired unit is displayed...

Страница 7: ...second Note that 10 sec provides the fastest response time 7 Set TARE This allows you to set a constant offset value which is then subtracted from the measured pressure For example if a TARE is set at...

Страница 8: ...adjustment enable disable Damping settings enable disable Sample rate setting enable disable Tare setting enable disable Custom engineering units set scale factor 4 Use the CONFIG key to scroll throug...

Страница 9: ...ng the MAX MIN button once will display the minimum pressure from memory Pressing the MAX MIN button again will display the maximum pressure from memory After about 2 seconds the gauge returns to norm...

Страница 10: ...se with the backlight off With intermittent use batteries could last a year or more There is a low battery icon in the upper left of the display It will appear when battery level is low Replace batter...

Страница 11: ...000 and 5 000 PSI 70 to 350 bar ranges 2X input pressure range 10 000 PSI 700 bar 1 5X input pressure range Overload Alarm indicate OL on display 1 2X input pressure range Temperature Compensation Fu...

Страница 12: ...rs at slow sample rate Low Battery Indicator icon is displayed near the end of battery life 9 0 Service Center Calibration or Repair Only qualified service personnel should perform calibration repairs...

Страница 13: ...1 5 15515 25858 51715 inHg 0 C 2 03602 2 0360 30 540 61 081 203 60 610 81 1018 0 2036 0 4072 0 6108 1 10180 20360 cmH 2 O 4 C 70 3089 70 309 1054 6 2109 3 7030 9 21093 35154 70309 cmH 2 O 20 C 70 4336...

Страница 14: ...LT Returns an error code from the error queue IDN Identification query Returns the manufacturer model number and firmware revision level of the Calibrator TARE Tares the offset pressure of the reading...

Страница 15: ...TEMP_UNIT Used to set temperature unit TEMP_UNIT Returns temperature unit Parameter Units Units Meaning Psi Pressure in pounds per square inch Bar Pressure in bars mBar Pressure in millibars Kg cm2 P...

Страница 16: ...e not connected 12 0 Warranty According to current terms of sale and delivery This warranty only covers defects in manufacture and becomes void if the instrument has been subject to unauthorised inter...

Страница 17: ..._ Temp Sensor Service request This instrument is sent for calibration input please tick off ___ Calibration as left ___ Check ___ Calibration as found and as left ___ Service ___ Accredited calibratio...

Страница 18: ......

Страница 19: ...SPK IPI 004 0200044 Rev A ATEX 10 12...

Страница 20: ...surement tasks from handheld field instruments to laboratory reference level bench top instruments JOFRA JF Marine Instruments A complete range of calibration equipment for temperature pressure and si...

Отзывы: