Field Wiring Diagrams
The following table can be used to find the correct field connection wiring diagram for the HVAC
System Type that is being installed.
Indoor Unit
Outdoor Unit
1 Stage
Cooling
2 Stage
Cooling
2 Step
Cooling
1 Stage
Heat Pump
2 Stage
Heat Pump
2 Step Heat
Pump
1 or 2 Stage Gas Furnace (PSC/CTM)
A
NA
NA
C
1
NA
NA
2 Stage VSPD Gas Furnace
A
A
B
C
1
C
1
D
1
COM Furnace
A
A
A
C
1
C
1
C
1
Air Handler (PSC/CTM)
A
NA
NA
C
NA
NA
VSPD Air Handler
A
A
B
C
C
D
COM Air Handler
A
A
A
C
C
C
Oil Furnace (PSC)
E
NA
NA
E
1
NA
NA
Oil Furnace (VSPD)
E
E
F
E
1
E
1
F
1
Enhanced Dehumidification Mode
See Notes
3, 4
1
For heat pumps matched with furnace, Dual Fuel must be enabled in the Mechanical Settings menu.
2
BAYSEN01ATEMPA is required for “restricted” mode of operation. See Remote Temperature Sensor Installation.
3
Enhanced Dehumidification Mode is not applicable with 2 Step outdoor products combined with legacy variable speed indoor
products that use BK for high stage airflow: System types B, D, or F.
4
Smart Continuous Fan and Cooling Droop are available for all models.
Gas Furnace or Air Handler
System Type A - 1 or 2 Stage Heating with 1 or 2 Stage Cooling
Fan G
Heat Stage 1 W1
Compressor Stage 1 Y1
24VAC Return R
24VAC Common B/C
Compressor Stage 2 Y2
BK
Heat Stage 2 W2
RED
GREEN
WHITE
YELLOW
BLUE
BROWN
Remote Temperature Sensor Connections and Operation:
Indoor sensor connected to RS1. Replaces internal sensor. RS2 not connected.
Indoor sensor connected to RS2. Averages temperature with internal sensor. RS1 not connected.
Indoor sensors connected to RS1 and RS2. Averages RS1 and RS2 sensor temperatures.
Internal sensor is not used.
Outdoor sensor connected to RS2. Reports outdoor temperature to comfort control.
Indoor sensor connected to RS1 and outdoor sensor connected to RS2. RS1 replaces the internal
sensor. RS2 reports the outdoor temperature to comfort control.
Note 1 - May be W or W1. For systems with more than one W terminal,
a field installed jumper may be required for W1 to W2 and W3.
(Note 1)
(Note 5)
(Note 2)
(Note 3, Note 4)
Note 2 - May be Y, Y1, or YLO
Note 3 - May be Y or Y2
Note 5 - R required for 2 stage cooling unit
Note 6 - For 2 Stage Cooling, outdoor unit contains two compressors
Note 7 - Remote sensor wiring is not polarized.
Note 8 - JP1 is an internal RC to RH jumper
Note 4 - Y2 only found on variable speed
furnace or air handler
(Note 6)
Outdoor Unit
Compressor Stage 1 Y1
24VAC Return R
24VAC Common B
Compressor Stage 2 Y2
ORANGE
JP1: Internal RC to
RH jumper
W1 HEAT
24RC
24RH
G Fan
W2/O
Y1 Comp
Y2 Comp
24C
RS1
RS1
Sensor Shield
Sensor Shield
H1
HC
RS2
RS2
Thermostat Connection
Remote
Sensor 1
Remote
Sensor 2