5. 1. 2 Template Parameter Edit 1 Page – NRPN Messages (all controls)
Changing the first option,
Control
, to NRPN (Non-registered Parameter Number) displays the following screen:
The first 5 of the subsequent options from left to right on the screen (from
DispType
to
MidiChan
) are the same as for CC Numbers,
so refer to section 5.1.1 for details. The last two options are as follows:
NRPN lsb
(Least Significant Byte): This page allows the Least Significant Bank controller number of the control to be set (see the Novation
online answerbase for a description of NRPN numbers). This can be set to a value between 0 and 127.
NRPN msb
(Most Significant Byte): This page allows the Most Significant Bank controller number of the control to be set (see the Novation
online answerbase for a description of NRPN numbers). This can be set to a value between 0 and 127.
If wanting to view the
NRPN lsb/msb
in hexidecimal then press the top ROW SELECT on the left. Pressing the same button again will
switch back to standard decimal display. The display type that is selected here (decimal/hexidecimal) will be carried through into the second
control display page in PLAY Mode, accessed by pressing either of the SCROLL UP buttons.
5. 1. 3 Template Parameter Edit 1 Page – RPN Messages (all controls)
Changing the first option,
Control
, on this screen to RPN (Registered Parameter Number) displays the following screen:
The first 5 of the subsequent options from left to right on the screen (from
DispType
to
MidiChan
) are the same as for CC Numbers, so
refer to section 5.1.1 for details. The last two options are as follows:
RPN lsb
(Least Significant Byte): This page allows the Least Significant Bank controller number of the control to be set (see the Novation
online answerbase for a description of RPN numbers). This can be set to a value between 0 and 127.
RPN msb
(Most Significant Byte): This page allows the Most Significant Bank controller number of the control to be set (see the Novation
online answerbase for a description of RPN numbers). This can be set to a value between 0 and 127.
If wanting to view the
RPN lsb/msb
in hexidecimal then press the top ROW SELECT on the left. Pressing the same button again will switch
back to standard decimal display. The display type that is selected here (decimal/hexidecimal) will be carried through into the second control
display page in PLAY Mode, accessed by pressing either of the SCROLL UP buttons.
Control
NRPN
DispType
0-127
Low Val
0
High Val
|127
Ports
ComnPORT
MidiChan
ComnCHAN
NRPN lsb
52
NRPN msb
68
Control
RPN
DispType
0-127
Low Val
0
High Val
|127
Ports
ComnPORT
MidiChan
ComnCHAN
RPN lsb
52
RPN msb
68
Содержание ReMOTE SL
Страница 44: ...Automapping within the Subtractor Synth Transport Controls for Sequencer Click here to return to SL diagram...
Страница 50: ...Automapping within the Malstrom Synth FEnv Invt Click here to return to SL diagram...
Страница 51: ...Automapping within the Malstrom Synth Transport Controls for Sequencer Click here to return to SL diagram...