B. Electric Models Only
IMPORTANT:
Figures shown are for non-reversing models ONLY. For reversing models contact the
factory.
IMPORTANT:
The dryer
must be
connected to the electric supply shown on the data label that is
affixed to the back side of the upper/top control door. In the case of 208 VAC or
230/240 VAC, the supply voltage
must match
the electric service specifications of
the data label exactly.
IMPORTANT:
The wire size
must be
properly sized to handle the related current.
WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME.
Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC
reserves the right to make changes in specifications at any time, without notice or
obligation.
APPROX.
AMP
DRA
W
IMPORTANT:
3 phase figures shown are for a 3 wire service ONLY.
MLE-75 (Electric)
E
LECTRICAL
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAM E. When ordering, specify exact vol tage.
NOTE:
A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type
of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
APPLIED VOLTAGE/PHASE
KW
208/1ø (60 Hz) 240/1ø (50/60 Hz) 208/3ø (50/60 Hz)
240/3ø (50/60 Hz)
380/3ø (50 Hz)
416/3ø (50 Hz)
460/3ø (60 Hz)
20
105
90
-- -
-- -
33
-- -
-- -
24
-- -
-- -
72
63
-- -
36
33
30
-- -
-- -
88
77
-- -
45
41
33
-- -
-- -
-- -
-- -
53
-- -
-- -
36
-- -
-- -
104
92
-- -
53
48
40
-- -
-- -
-- -
-- -
-- -
59
-- -