background image

ADJ Products, LLC  -  www.adj.com - Royal 3D II Instruction Manual Page 9

ADJ Products, LLC  -  www.adj.com - Royal 3D II Instruction Manual Page 10

 Royal 3D II   

 

                                           Set Up

 Royal 3D II   

 

                                           Set Up

DMX cable must be daisy chained and cannot be split.

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

1

2

3

Termination reduces signal errors and

avoids signal transmission problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

Содержание ROYAL 3D II

Страница 1: ...Slave configuration The Royal 3D II has two operating modes sound active or controlled via DMX This fixture is suitable for theaters studios retail stores and other similar locations For best results...

Страница 2: ...or cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should b...

Страница 3: ...sure In the laser safety regulation it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not o...

Страница 4: ...a DMX line at the beginning at the end or anywhere in the middle Therefore the first fixture controlled by the controller could be the last fixture in the chain When a fixture is as signed a DMX addre...

Страница 5: ...rminator is a 110 120 ohm 1 4 watt resistor which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your da...

Страница 6: ...into DMX mode press and hold the MENU button for at least 3 sec onds SLND This will let you set unit as a slave in a master slave configuration 1 Press the MENU button until SLND is displayed press EN...

Страница 7: ...ress ENTER to confirm your desired set up LED With this function the LED display will turn off after 2 minutes 1 Press the MENU button until LED is displayed press ENTER Royal 3D II System Menu Royal...

Страница 8: ...o adjust the sound sensitivity press the MENU button until SENS is displayed and press ENTER Use the UP or DOWN buttons to adjust sensitivity 4 The optional UC3 Controller not included may be used to...

Страница 9: ...lass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates I...

Страница 10: ...after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization was issued to...

Отзывы: