SENS -
Sound sensitivity control.
1. Press the MENU button until “SENS” is displayed, press ENTER.
2. The display will show a number between 0-100. Press the UP or
DOWN buttons to adjust the sound sensitivity. 0 being the least sen-
sitive and 100 the most sensitive.
3. Press the ENTER to confirm.
DNST
-
This mode can be used as a precaution mode, that
in case the DMX signal is lost, the operating mode chosen
in the setup is the running mode the fixture will go into when
the DMX signal is lost. You can also set this as the operat-
ing mode you would like the unit to return to when power is
applied.
1. Press the MENU button until “DNST” is displayed, press
ENTER.
2. Either “MAST”, “BLND”, or “LAST” will be displayed. Choose
an operating mode you would like the unit to start up in when
power is applied or the DMX signal is lost.
• MAST (Master Slave) - If the DMX signal is lost or power is
applied, the unit will automatically go into Master Slave mode.
• BLND (Blackout) - If the DMX signal is lost or power is applied,
the unit will automatically go into stand by mode.
• LAST (Last State) - If the DMX signal is lost the fixture will stay
in the last DMX set up. If power is applied and this mode is set,
the unit will automatically go into the last DMX set up.
3. Press ENTER to confirm your desired set up.
LED
-
With this function the LED display will turn off after
2 minutes.
1. Press the MENU button until “LED” is displayed, press ENTER.
Royal 3D II System Menu
Royal 3D II System Menu
2. Either “ON” or “OFF” will now be displayed. Press the UP or DOWN
buttons to select “ON” to keep the LED display on at all times, or
“OFF” to allow the LED display to turn off after 2 minutes. Press any
button to turn on the LED display again.
3. Press ENTER, and then press and hold the MENU button for at least
three seconds to confirm.
DISP
-
This function will “flip” the LED display 180º.
1. Press the MENU button until “DISP” is displayed, press ENTER.
2. Either “dISP” or “dSIP” will now be displayed. Press the UP or
DOWN buttons to select one or the other.
3. Press ENTER, and then press and hold the MENU button for at least
three seconds to confirm.
TEST
-
This function will run a self test program.
1. Press the MENU button until “TEST” is displayed, press ENTER.
2. The unit will now run a self test. Press the MENU button to exit.
FHRS
-
With this function you can display the running
time of the unit.
1. Press the MENU button until “FHRS” is displayed, press ENTER.
2. The running time of the fixture will now be displayed. Press MENU
to exit.
VER
-
This will display the software version.
1. Press the MENU button until “VER” is displayed. Press the ENTER
button and the software vesion will be displayed.
2. Press the MENU button to leave this function.
RSET
-
Use this function to reset the unit.
1. Tap the MENU button until “RSET” is displayed, press ENTER.
2. The fixture will now reset.