20 Gear Drive, Plymouth Industrial Park, Terryville, CT 06786 page: 10 of 49
Tel: (860) 585-1254 Fax: (860) 584-1973 Web: www.amci.com
2600-13 Press Control Module
MicroLogix 1500 & CompactLogix Resolver Module
Revision 2.1
Connectors Pinout
The peripheral signals are brought into the 2600-13 module through an 18-pin connector AB 1769-RTBN18.
This connector is included with the 2600-13 module.
Main Board Connector
Pre made cables are available from AMCI. These cables come with a Bendix connector that mates with the
resolver transducer. The other end is pigtailed at the factory for easy connection to the 18 pin connector that
is included with the 2600-13 module. This cable has a part number of CTL-X, where X equals the length in
feet.
The CTL-X cable shown below is used to connect an AMCI single resolver transducer to the 2600-13
module.
-RxD (Slave Input -)
-TxD (Master Output -)
Cable Shields
-Z Quadrature Output
-B Quadrature Output
-A Quadrature Output
-COS (S2 resolver signal)
-SIN (S1 resolver signal)
-REF (R2 resolver signal)
+RxD (Slave Input +)
+TxD (Master )
Ground
+Z Quadrature Output
+B Quadrature Output
+A Quadrature Output
+COS (S4 resolver signal)
+SIN (S3 resolver signal)
+REF (R1 resolver signal)
1
3
5
7
9
11
1
13
15
17
2
4
6
8
10
12
14
16
18