20 Gear Drive, Plymouth Industrial Park, Terryville, CT 06786 page: 16 of 49
Tel: (860) 585-1254 Fax: (860) 584-1973 Web: www.amci.com
2600-13 Press Control Module
MicroLogix 1500 & CompactLogix Resolver Module
Revision 2.1
Global Machine Offset Data
Preset Input: This parameter defines the input that, when energized, will set the Scaled Position data equal to
the Preset Value.
2611-13 module range: 0 to 15
2612-13 module range: 0 to 23
2613-13 module range: 0 to 31
Preset Value: The scaled position is set to this value when the
Preset Input
is energized. The module
automatically recalculates the Scaled Machine Offset.
The Preset Value has a range of (0 to Resolver Rollover Position)
The factory default is 0
Nudge Up Input: This parameter defines the input that, when energized, will increase the Scaled Machine
Offset and the Preset Value by the Nudge Up Value. Because the Scaled Machine Offset is
being changed, the Scaled Position data will also be changed.
2611-13 module range: 0 to 15
2612-13 module range: 0 to 23
2613-13 module range: 0 to 31
Nudge Up Value: The Offset and Preset values are increased by this value when the Nudge Up Input is
energized.
The Nudge Up Value has a range of (0 to Resolver Rollover Position)
The factory default is 0
Nudge Down Input: This parameter defines the input that, when energized, will decrease the Scaled Machine
Offset and the Preset Value by the Nudge Down Value. Because the Scaled Machine
Offset is being changed, the Scaled Position data will also be changed.
2611-13 module range: 0 to 15
2612-13 module range: 0 to 23
2613-13 module range: 0 to 31
Nudge Down Value: The Offset and Preset values are decreased by this value when the Nudge Down Input is
energized.
The Nudge Down Value has a range of (0 to Resolver Rollover Position)
The factory default is 0