Output Being Programmed: This parameter defines to what output the remaining Speed Compensation and
Timed Output parameters are being assigned to.
2611-13 module range: 0 to 15
2612-13 module range: 0 to 23
2613-13 module range: 0 to 31
Advance based on Distance (in counts) and Speed (in RPM)
Lead Position Distance: This parameter defines the distance, in counts, to advance the beginning, the
OFF to ON edge, of the From To Setpoint window.
This parameter has a range of (0 to Resolver Rollover Position)
Lead Speed RPM: This parameter sets the speed at which the resolver must be turning in order to
compensate by
Lead Position Distance
.
This parameter has a range of 0 to 32767 and can only be equal to zero when the
Lead Position Distance is equal to 0.
Trailing Position Distance: This parameter defines the distance, in counts, to advance the ending, the ON
to OFF edge, of the From To Setpoint window.
This parameter has a range of (0 to Resolver Rollover Position)
Trailing Speed RPM:
This parameter sets the speed at which the resolver must be turning in order to
compensate by
Trailing Position Distance
.
This parameter has a range of 0 to 32767 and can only be equal to zero when the
Trailing Position Distance is equal to 0.
Advance based on Time (in milliseconds)
Lead Advance Time: This parameter defines the time to advance the beginning, the OFF to ON edge, of
a setpoint window for Speed Compensation.
This parameter has a range of 0 to 32767.
Trail Advance Time: This parameter defines the time to advance the ending, the ON to OFF edge, of a
setpoint window for Speed Compensation.
This parameter has a range of 0 to 32767.