CHAPTER 3: USING STA SERIES CONTROL FUNCTIONS
STA SERIES AC CONTROLS
3-8
990-351
Section V: Monitor Counts Screen
To get the
MONITOR COUNTS
Screen, press the
MONITOR
button on the Control Panel, go to COUNTS
at the bottom of the screen, highlight the
symbol and press the Data + key.
The
MONITOR COUNTS
screen consists of the
following settings and readouts shown on the
right.
SCHEDULE #00
MONITOR COUNTS
WELD COUNT
0001
STEP
#
01
WELD COUNT LIMIT=2990
STEP COUNT
0001
SET WELD COUNT=0
ELECT.VALVE
01
Back
SCHEDULE #
-
The schedule number is used to select a particular schedule whose associated monitor
data is to be displayed. The schedule is programmable from
00
to
63
, the default being the last schedule
saved. Pressing the
PROGRAM/SAVE
pushbutton toggles between the
Program
and
Run Modes
. Placing
the system in the
Run Mode
automatically saves the currently displayed values for the schedule.
If any changes have been made in any data field,
the system will prevent the operator from
changing to a different schedule until the
changes have been accepted or rejected. The
operator will get the following message:.
MODIFIED SCHEDULE NOT SAVED.
PRESSING THE PROGRAM/SAVE KEY SAVES
MODIFICATIONS, THEN PRESS DESIRED
SCREEN BUTTON AFTER SAVING.
OR PRESS PLUS OR MINUS KEY TO LOSE
If no data field has been changed, the software will allow control buttons on the panel to function.
Entering a new
SCHEDULE #
shall cause the Control to switch to that new schedule and display it on the
screen.
WELD COUNT
– Displays the total number of welds for the schedule. This data is not programmable.
WELD COUNT LIMIT
– Programmable from
0000
to
9999
with the default being
0000
, which sets the weld
count limit to
OFF
. When the
WELD COUNT
reaches this user programmed number, an error signal is
transmitted from the Fault output and a fault message screen
WELD COUNT REACHED WELD COUNT
LIMIT
is displayed. (See Error Messages in Chapter 4.)
SET WELD COUNT = 0
– Placing the cursor at the
symbol and pressing the plus key, sets the weld
count of a schedule to zero.
STEP #
-- Displays what step the schedule is on. This data is not programmable. When the Stepper is
off,
00
is displayed. When the
Stepper
is reset, this value updates after the following weld.
STEP COUNT
– Displays the current weld count of the step. This data is not programmable. When the
Stepper is off,
0000
is displayed.
ELECT. VALVE
– This item displays the electrode valve number used with this schedule. The valve is
selected using the
Schedule
screen.
Содержание Miyachi Unitek STA-100A
Страница 1: ...990 351 Rev H AC WELDER STA SERIES OPERATION MANUAL...
Страница 18: ...CHAPTER 1 DESCRIPTION STA SERIES AC CONTROLS 1 4 990 351 STA 100A Series Major Components Typical...
Страница 24: ......
Страница 28: ......
Страница 48: ......
Страница 64: ......
Страница 68: ...CHAPTER 5 MAINTENANCE STA SERIES AC CONTROLS 5 4 990 351...
Страница 78: ......
Страница 82: ...APPENDIX A TECHNICAL SPECIFICATIONS STA SERIES AC CONTROLS A 4 990 351 STA 200A AC Control Control...
Страница 86: ...APPENDIX B ELECTRICAL AND DATA CONNECTIONS STA SERIES AC CONTROLS B 4 990 351 Input Output Control Signals...
Страница 90: ......
Страница 96: ...APPENDIX D SYSTEM TIMING STA SERIES AC CONTROLS D 2 990 351 Continuous Seam Weld...
Страница 98: ...APPENDIX D SYSTEM TIMING STA SERIES AC CONTROLS D 4 990 351 Spot Welding...
Страница 102: ......
Страница 104: ......
Страница 108: ......
Страница 112: ......
Страница 140: ......
Страница 144: ......
Страница 154: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...