Supervisor 2000 Installation Instructions
Page 24
For Assistance: [email protected] +1 (909) 591-8431 PUD1601R6-1
Ethernet Communication (Optional)
1. Locate the CPU board in the master / center cabinet.
2. Connect the Ethernet cable to the Ethernet Port
[Figure 25].
It is assumed that Ethernet cabling has been run to the
turnstile via conduit and pulled through the conduit opening in
Step 6 of the Anchoring the Turnstile section.
NOTE
Post-Installation Functions Check
Alvarado turnstiles are thoroughly inspected and tested for proper performance prior to being shipped. Perform the following
function checks to verify the turnstiles have been installed properly and are fully operational. If any problems are encountered
during the functions check, refer to the Troubleshooting section on Page 31.
Before beginning the Post-Installation Functions Check, please read the following brief descriptions of the three SU2000 passage
modes. More information on SU2000 passage modes can be found in the
SU2000 User Guide
.
(Flashing)
Passage Mode
Description
User Status
Display
Controlled Passage
Upon receipt of an authorization signal from
an access control system, a single passage
is allowed. Controlled Passage mode can be
either single direction or bi-directional.
Free Passage
An authorization signal is not required for a
user to pass through the lane. Free Passage
mode can be either single direction or bi-
directional.
No Passage
No passage is allowed. Valid electronic
credentials are ignored. Any passage will set
off violation alarms. No Passage mode can
be either single direction or bi-directional.
Passage Modes
Ethernet
Port
CPU Board
Figure 25