Baseplate Assembly (Optional)
An optional SU2000 baseplate may be purchased with the SU2000 turnstile. A baseplate enables installation of the SU2000
turnstile on a solid foundation without the need to drill holes in the ground. The baseplate also provides concealed conduit channels
for wiring all power and communication cables. Baseplates come in different sizes and may be bridged together with other
baseplates for multiple turnstile lanes. The following information will guide the installer in assembling the baseplate:
Examine the area with a measuring tape and carefully mark the location where the baseplate(s) will be placed. An external power
source and external data cables (required for GateKeeper and external controls), must be accessible and provided to the turnstile.
The side plate on the baseplate must be removed in order to provide external power/data (or the side plate may be drilled with
appropriate holes as needed for concealment). Determine which side plate to remove and remove it by unfastening the (4) screws
as shown in [Figure 13].
Place the baseplate carefully in the marked location. The installation process continues in the following sections. Follow the
instructions there in order to pull the appropriate cables through the conduit openings.
For multiple lanes, baseplates may be attached together. Holes are provided for bridging multiple baseplates together. The side
plate must be removed in order to bridge the baseplates together side by side. Secure the baseplates side by side by fastening the
(4) screws provided to the support from the other baseplate.
Holes for bridging multiple baseplates
Anchor Location
Conduit holes for power and communication cables
(use separate conduits for power and communication cables)
Baseplate
Figure 13