background image

Supervisor 2000 Installation Instructions

PUD1601R6-1 

       For Assistance: [email protected]  +1 (909) 591-8431  

Page 21

I/O Control Board (13-0328 Rev. F) Terminal Descriptions

J2 Output Contacts

J1 Input Contacts

Pin #

Pin  
Name

Function 
Description

Contact 
Type

Function & Behavior 

Description

Pin #

Pin  
Name

Function 
Description

Contact 
Type

Function & Behavior 

Description

1

GNDX

Ground

N/A

Common output signal 

ground.

1

GND

Ground

N/A

Common input ground signal.

2

ENTACX

Authorized 

Passage 

Entry

MDC

An output occurs when an 

authorized entry passage is 

completed. 

2

ENTACC

Good Card 

Entry

MDC

Opens the turnstile for one 

authorized passage until 

passage occurs or timeout.

3

ENTUCX

Unauthorized 

Passage 

Entry

MDC

An output occurs when an 

unauthorized entry passage 

is completed.

3

ENTREJ

Bad Card 

Entry

MDC

Illuminates the entry side 

RED User Status Icon for 2 

seconds.

4

ENTALRX

Unauthorized 

Presence 

Entry

MDC

Not used on the SU2000.

4

ENTPAS

Free 

Passage 

Entry

SDC

Sets the turnstile to Free 

Passage mode in the entry 

direction.

5

ENTCLSX

N/A

N/A

Reserved

5

ENTCLS

Close 

Direction 

Entry

SDC

Sets the turnstile to No 

Passage mode in the entry 

direction.

6

EXTACX

N/A

N/A

Reserved

6

ENTOVR

Single 

Override 

Entry

MDC

Opens the turnstile for one 

authorized passage in the 

entry direction independent 

of the access control system. 

(Typically used for button at 

security desk.)

7

GNDX

Ground

N/A

Common output signal 

ground.

7

ENTSERVICE

Visitor Mode

SDC

Places the turnstile in Free 

Passage in both the entry and 

exit directions. (Typically used 

with toggle switch at security 

desk.)

8

EXTACX

Authorized 

Passage Exit

MDC

An output occurs when an 

authorized exit passage is 

completed.

8

GND

Ground

N/A

Common input ground signal.

9

EXTUCX

Unauthorized 

Passage Exit

MDC

An output occurs when an 

unauthorized exit passage is 

completed.

9

EXTACC

Good Card 

Exit

MDC

Opens the turnstile for one 

authorized passage until 

passage occurs or timeout.

10 EXTALRX

Unauthorized 

Presence 

Exit

MDC

Not used on the SU2000.

10 EXTREJ

Bad Card 

Exit

MDC

Illuminates the exit direction 

RED User Status Icon for 2 

seconds.

11 EXTCLSX

N/A

N/A

Reserved

11 EXTPAS

Free 

Passage 

Exit

SDC

Sets the turnstile to Free 

Passage mode in the exit 

direction.

12 EXTOVRX

N/A

N/A

Reserved

12 EXTCLS

Close 

Direction 

Exit

SDC

Sets the turnstile to No 

Passage mode in the exit 

direction.

13 BLKSEN

Blocked 

Sensor

MDC

An output occurs when 

a sensor is blocked for a 

defined length of time (default 

15 seconds).

13 EXTOVR

Single 

Override 

Exit

MDC

Opens the turnstile for one 

authorized passage in the 

exit direction independent of 

the access control system. 

(Typically used for button at 

security desk.)

14 SOUT-1

Free 

Passage Exit

MDC

An output occurs when there 

is a passage in the exit 

direction.

14 EXTSERVICE Horizontal 

Arm 

Breakaway

SDC

Not used on the SU2000.

15 GNDX

Ground

N/A

Common output signal 

ground.

15 GND

Ground

N/A

Common input ground signal.

16 DHO

Loitering

MDC

An output occurs when a 

user loiters in the lane after 

the allotted time to close 

after passage (default 12 

seconds).

16 N/O

Normally 

Open

SDC

Not used on the SU2000.

17 BREAKAWAY

Barrier Arm 

Broken Away

MDC

Not used on the SU2000.

17 BARDISABLE Disables 

Barrier Arms

SDC

Not used on the SU2000.

18 SOUT-2

Crawl 

Detection

MDC

An output occurs when the 

crawl sensors detect an 

unauthorized passage.

18

EMROVR

Emergency 

Override

SDC 

(N/O or 

N/C)

Turnstile opens in the exit 

direction. Turnstile is inactive 

until SDC is removed, or 

contact is reestablished if N/C 

jumper is enabled. (Typically 

used for fire alarm or life 

safety systems.)

19 SOUT-3

N/A

N/A

Reserved

19 SINPUT

N/A

N/A

Reserved

20 GNDX

Ground

N/A

Common output signal ground.

20 GND

Ground

N/A

Common output signal ground.

Содержание SU2000

Страница 1: ...Company Inc 12660 Colony Street Chino CA 91710 Phone 1 909 591 8431 Fax 1 909 628 1403 support alvaradomfg com www alvaradomfg com PUD1601R6 1 Supervisor 2000 SU2000 Barrier Free Optical Turnstile Ins...

Страница 2: ...11 Pre Installation Instructions 12 Side Panel Removal 12 Lid Removal 12 End Panel Removal 13 Turnstile Layout 14 Baseplate Assembly Optional 15 Installation Instructions 16 Anchoring the Turnstile 16...

Страница 3: ...and operations information must be adhered to Note the following precautions For indoor use only Use only skilled individuals to install and service the turnstile DO NOT operate the turnstile if it h...

Страница 4: ...act Alvarado Center Cabinets are used to create additional lanes for multi lane configurations Each additional lane includes the parts below Single Lane Parts List Center Cabinet Parts List Per Center...

Страница 5: ...n the entry and exit directions SU2000 Cabinets The master cabinet contains the main turnstile controller I O control board power supply sensor receivers and a power button located at the base on the...

Страница 6: ...ng Ethernet cabling to the SU2000 master and center cabinets provides a number of benefits 1 It allows implementation of Alvarado s TCP IP control and monitoring software 2 It allows easy implementati...

Страница 7: ...8431 Page 7 All dimensions are approximate Space Requirements 28 Lane Plan View Elevation View Footprint Drawing 28 Single Lane Plan Elevation Footprint Drawing Figure 3 For ease of installation and s...

Страница 8: ...PUD1601R6 1 All dimensions are approximate Space Requirements 36 Lane Elevation View Plan View Footprint Drawing 36 Single Lane Plan Elevation Footprint Drawing Figure 4 For ease of installation and s...

Страница 9: ...8431 Page 9 inches mm All dimensions are approximate Space Requirements 28 36 Optional Baseplates 28 Baseplate Figure 5 36 Baseplate Figure 6 For ease of installation and servicing Alvarado recommends...

Страница 10: ...n the high voltage power line to further protect electronics NOTE The conduit openings for each cabinet are 8 x 2 80 203mm x 71mm The three required conduits will fit in these areas Figure 7 Primary P...

Страница 11: ...ginning the installation Card readers or other physical access devices may be installed to the end panels on the right hand sides of the lane or on adjacent pedestals Card readers physical access devi...

Страница 12: ...the lid screws located on the cabinet end panels as shown in Figure 9 There is one lid screw per side 2 Using a 2 Phillips head screwdriver remove the two 2 lid screws 3 Gently lift the lid in an upw...

Страница 13: ...8431 Page 13 End Panel Removal 1 Locate the eight 8 end panel screws located on the inside of the frame Figure 10 2 Using a 2 Phillips head screwdriver remove the eight 8 end panel screw 3 Gently rem...

Страница 14: ...the master controller cabinet components are facing the slave cabinet components and the power button s are located on the secured side The Lane 1 master cabinet is always the right most cabinet in re...

Страница 15: ...trols must be accessible and provided to the turnstile The side plate on the baseplate must be removed in order to provide external power data or the side plate may be drilled with appropriate holes a...

Страница 16: ...th respect to the floor and other cabinets A Measure the distance from the inside wall of one cabinet to the inside wall of the other cabinet on both the entry and exit side of the lane for a consiste...

Страница 17: ...ctly 5 Insert the anchors into each drilled hole Figure 17 The threaded end of the anchor must be inserted into the hole first Use a rubber mallet to tap the anchors into place if needed Ensure that t...

Страница 18: ...Card readers may also be installed on an adjacent pedestal Contact Alvarado for information on obtaining pedestals Card readers require separate power input do not pull this power from the SU2000 pow...

Страница 19: ...a licensed electrician perform this procedure in accordance with all applicable local codes The primary wiring lines for 110VAC and 220VAC consist of the following Terminal 110V 220V Ground Green Gre...

Страница 20: ...ge free dry contacts with the exception of the fire alarm input which can be configured via jumper on the I O control board to accept either a normally open or normally closed N C sustained contact MD...

Страница 21: ...t MDC An output occurs when an unauthorized exit passage is completed 9 EXTACC Good Card Exit MDC Opens the turnstile for one authorized passage until passage occurs or timeout 10 EXTALRX Unauthorized...

Страница 22: ...Key Control If this option has been ordered for your turnstiles two 3 position key switches are installed on the turnstile Turning the key to one of the three positions allows each turnstile direction...

Страница 23: ...the ENTPAS and GND terminals 2 Using a wire jumper connect the ENTPAS and GND terminals Figure 23 Exit Direction 1 Locate the EXTPAS and GND terminals 2 Use a wire jumper to connect the EXTPAS and GN...

Страница 24: ...during the functions check refer to the Troubleshooting section on Page 31 Before beginning the Post Installation Functions Check please read the following brief descriptions of the three SU2000 passa...

Страница 25: ...such as a pencil or pen push the power button 2 The power up cycle takes less than one minute to complete Two chimes sound during the power up cycle to indicate status Ascending Chime Operating syste...

Страница 26: ...e turnstile is connected Valid access cards are on hand for activating the turnstile CONTROLLED PASSAGE MODE Unauthorized Entry Exit Authorized Entry Exit Unsecured Side Unauthorized Entry shown Autho...

Страница 27: ...ow is flashing No alarm sounds as the user enters and exits the turnstile Enter the turnstile User status display red icon is illuminated Unauthorized Entry alarm sounds No Passage Entry Exit Unsecure...

Страница 28: ...ning the key to one of three positions overrides all existing settings placing the turnstile in Controlled Passage mode Free Passage mode or No Passage mode depending on the orientation of the key Ref...

Страница 29: ...h programs and files field 5 Enter the following command ping XXX XXX X XXX where XXX XXX X XXX is the IP address of the turnstile Figure 30 6 A successful ping will result in the message shown in Fig...

Страница 30: ...y 2 Lane Functionality User status displays are functioning properly Auditory alarms are playing back correctly 3 Access Control Integration Installed card readers are successfully reading credentials...

Страница 31: ...ntact cleaner lubricant to connector pins and reseat Retry operation If condition persists perform the same process on the 16 pin connectors going into and out of the light boards and sensor boards Re...

Страница 32: ...Multi Lane Conduit Requirements Two Lane Configuration Three Lane Configuration LANE 2 LANE 3 LANE 1 Master Cabinet Center Cabinet Center Cabinet Slave Cabinet Slave Cabinet Center Cabinet Master Cabi...

Страница 33: ...09 591 8431 Page 33 Revision History Revision Date Author Description 6 0 02 12 15 A Flores Updated to new optical electronics configuration 6 1 07 17 15 A Flores Updated crossover cable length to 11...

Страница 34: ...2014 Alvarado Manufacturing Company Inc This work may not be reproduced published or redistributed in whole or in part without the express prior written permission of Alvarado...

Отзывы: