Programming via AlulaConnect (cont.)
Programming BAT-Fire Phone 2 trouble triggers
• Select “Edit” to the right of Phone 2
• Check all desired Phone 2 triggers
• Power Fail
• Cover Tamper
• Cell Fail
• Ethernet Fail
• Central Station Fail
• Central Station Trouble
• Select “Save”
Programming BAT-Fire PGMx port for FACP/burg panel point capture
• Select “Edit” on the desired input port
•
Select “Configure as Input”
•
Enter required configuration input data
• Sensor Type
• Report Code
•
Zone Number
• Input Name
• Select “Save”
Programming BAT-Fire PGM4 port as trouble trigger
• Select “Edit” on the desired output port
•
Select “Configure as Output”
• Name output as desired
• Check all desired trouble triggers
• Power Fail
• Cover Tamper
• Cell Fail
• Ethernet Fail
• Central Station Fail
• Central Station Trouble
• Select “Save”
Programming BAT-Fire central station receiver(s)
• Select primary and backup (optional) receivers
• Adjust Supervision Interval based on wiring mode
• 6 hours (default) complies with UL 864 10th edition requirement for dual path
communications
•
For specific AHJ guidance, sole path mode, ULC-S559 or ULC-S304 compliance, refer to
Table 1 for Supervision Interval settings
• Select “Save”
Programming BAT-Fire PGM3 port as ringback trigger
• Select “Edit” on the desired output port
•
Select “Configure as Output”
• Name output as desired
• Check the UL Ringback trigger
• Select “Save”