3
Figure 1. Phone Line Capture Wiring
• Both Phone line 1 and 2 must be connected to the FACP/burg panel. The FACP/burg panel
must be configured to supervise the phone lines.
• Most FACPs/burg panels can be supported for event reporting as long as it provides Tip &
Ring connection and transmits events in Contact ID format.
•
Warning: do not connect telephone company lines to the BAT-Fire. Attention: ne connectez
pas les lignes de votre compagnie téléphonique au BAT-Fire.
• It is recommended to use separate cables for Tip & Ring 1 and Tip & Ring 2.
• Failures and Troubles are communicated to FACP/burg panel via the BAT-Fire dropping
voltage to Phone 2. Refer to Programming section on how to configure Phone 2 trouble
triggers.
• Stranded wire gauge range: 24-14AWG.
• If FACP/burg panel has one phone line, PGM4 should be wired as the trouble indicator (see
Figure 2). This configuration is common in commercial burg applications.