BAT-Fire

™ 

Communicator  

Connect Family

BAT-Fire

 

is a device that connects to an intrusion or fire alarm 

control panel (FACP) and provides central station alarm 
reporting.  

Features

•  Supports 12V and 24V regulated FACPs/burg panels

•  Alarm capture via phone line interface or standard      

FACP/burg panel points

•  Supports Contact ID (CID) reporting format
•  Dual Path: Ethernet (primary) with Cellular (backup)
•  Sole Path: Ethernet or Cellular 
•  Platform visibility through AlulaConnect™
•  Trouble event detection and reporting

•  Four programmable input/output ports

•  At-a-glance system status via front-panel LEDs
• 

UL 864 10th edition commercial fire certification

• 

ULC-S559 commercial fire 

certification

• 

UL 1610 commercial burg certification

• 

ULC-S304 commercial burg certification (Security Level II 

installations)

Scan QR for most up to date 

manual, features, and compatibility

Operation

Phone line capture

BAT-Fire provides two PSTN interfaces for the FACP/burg panel’s DACT phone line connections. 

BAT-Fire’s DACT phone interface connection provides phone line voltage, dial tone, ringback tone 

and all required CID protocol signaling. The BAT-Fire receives CID events from the FACP/burg 

panel’s DACT and then relays the CID events to the central station receiver.

Point capture

The BAT-Fire provides inputs that can be used to monitor an FACP’s alarm, AC fail, and trouble 

points (dry contact outputs). In this topology BAT-Fire inputs will be connected to the FACP points 

(dry contact outputs). BAT-Fire will continually monitor the state of the FACP points (dry contact 

outputs). A state change on a BAT-Fire monitored FACP point (dry contact output) will be report-

ed to the central station. (Refer to the Programming section describing how to set-up a BAT-Fire 

input for FACP point capture.) 

Note:

 for UL 864 10th edition, 

this configuration may only be used for panels with one input zone. 

9th edition and earlier permitted this method for multiple protection zones.

Central station communication 

 

The BAT-Fire can be configured to provide dual path connectivity using Ethernet/broadband 

and cell or single path connectivity using either Ethernet/broadband or cell to Bosch Conettix 

D6100IPv6 receivers at the central station. 

BAT-Fire, AT&T™ (BAT-FIRE-ATT)

BAT-Fire, Verizon™ (BAT-FIRE-VZ) 

 

Содержание BAT-Fire AT&T

Страница 1: ...T Fire s DACT phone interface connection provides phone line voltage dial tone ringback tone and all required CID protocol signaling The BAT Fire receives CID events from the FACP burg panel s DACT and then relays the CID events to the central station receiver Point capture The BAT Fire provides inputs that can be used to monitor an FACP s alarm AC fail and trouble points dry contact outputs In th...

Страница 2: ...ation is complete 9 Press the Config button on the BAT Fire for 2 seconds to enable programming Program the BAT Fire via AlulaConnect see Programming section 10 Close the cover Confirm POWER TROUBLE and COMM LEDS are green 11 After installing BAT Fire or modifying any FACP burg panel programming verify proper operation and reporting of all event codes using your FACP burg panel installation manual...

Страница 3: ...ompany lines to the BAT Fire Attention ne connectez pas les lignes de votre compagnie téléphonique au BAT Fire It is recommended to use separate cables for Tip Ring 1 and Tip Ring 2 Failures and Troubles are communicated to FACP burg panel via the BAT Fire dropping voltage to Phone 2 Refer to Programming section on how to configure Phone 2 trouble triggers Stranded wire gauge range 24 14AWG If FAC...

Страница 4: ...2 by Honeywell relay The panel must support the relay contacts as indicated above NC for alarm and AC FAIL and NO for Trouble and battery calculation shall consider the additional current draw into the PGM s during the Normal Standby state Use 4 7k ohm 1 4 Watt minimum resistors not included PGM ports are not supervised Only panels without supervisory signaling can use this setup For UL 864 10th e...

Страница 5: ... not operational CS Fail Signal transmission to the central station is not operational Trouble Conditions The following trouble conditions can be communicated by BAT Fire to the FACP burg panel For UL 1610 installations refer to Programming section on how to configure BAT Fire s PGM3 as a ringback trigger A UL approved siren such as Honeywell Model 747 must be used for ringback The ringback featur...

Страница 6: ...tual interface supervision for both primary and backup Ethernet Remote Programming On site or Remote Enabled or Disabled Disabled Disabled Enabled or Disabled If Disabled Installer must press Config button onsite Phone 2 Trouble Trigger If using Phone Line capture Figure 1 Power Fail Cover Tamper Cell Fail Ethernet Fail CS Fail CS Trouble CS Fail CS Fail Cover Tamper CS Fail Figure 1 Any Enabled T...

Страница 7: ... and backup cellular Sole Path Cell 60 seconds 6 hours 1 hour 180 seconds or shorter 180 seconds or shorter Turn off Ethernet supervision Turn off virtual interface supervision for both primary and backup Ethernet Remote Programming On site or Remote Enabled or Disabled Disabled Enabled or Disabled Enabled or Disabled If Disabled Installer must press Config button onsite Phone 2 Trouble Trigger If...

Страница 8: ...sired output port Select Configure as Output Name output as desired Check all desired trouble triggers Power Fail Cover Tamper Cell Fail Ethernet Fail Central Station Fail Central Station Trouble Select Save Programming BAT Fire central station receiver s Select primary and backup optional receivers Adjust Supervision Interval based on wiring mode 6 hours default complies with UL 864 10th edition ...

Страница 9: ...ware is up to date Device Unused Cellular signal bar LEDs indicate the quality of the cellular connection A minimum of two signal bar LEDs is recommended Number of Signal Bar LEDs Lit Cellular Signal Strength 0 Bad 1 Marginal 2 Acceptable 3 Good 4 Best Operation and Indicator Overview Events are reported to the central station receivers and the Alula platform event system All events use Contact ID...

Страница 10: ... connected 2 Ensure router is powered 3 Ensure UDP ports 1234 and 1235 are open in router modem settings 4 Ensure account is properly configured Cellular LED Off 1 Verify sufficient signal strength for cellular see cellular signal bar table in Operation and Indicator Overview section 2 Ensure account is properly configured Comms LED Yellow 1 Verify the reporting path and ensure the receiver is pro...

Страница 11: ...Collector An output that when engaged shunts current to ground Point A single FACP burg panel output that is either on or off Point Capture The operation mode of BAT Fire connected to the FACP burg panel output s and sensing a trouble or alarm condition Additionally the operation of the FACP burg panel connected to a BAT Fire output and sensing a trouble or communication condition PSTN Public Swit...

Страница 12: ...020BG95M1 This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada TRADEMARKS Alula BAT Fire and AlulaConnect are trademarks owned by Alula Holdings LLC AT T is a trademark of AT T Intellectual Property II L P Verizon is a trademark of Verizon Trademark Services LLC Taoglas is a trademark of Taoglas Group Holding...

Отзывы: