Neptune_GB_Ver.2.0_10/03
7.
Adjustment / Test
400V
400V
230V
230V
400V
400V
230V
230
V
Electrical connection
Some models are equipped with a star delta switch S2 to change between 230 V and 400 V.
M
1~
A1
A2
K2
T1
4
8V AC
24V AC
U2 V2 W2
M
3~
V1 W1
U1
M1
L2 L3
L1
X11
T2
M2
PE
13 (17)
14 (18)
1
3
5
2
4
6
A1
A2
K1
1
02
S1
8a
7a
6a
5a
4a
3a
2a
1a
1
2
3
4
5
6
8
7
K1
S2
F11
11
14, 24
1a
2a
2
1
7
6
Xma
XMb
3
1
2
4
5
6
8
400V
230V
Com
On this diagram the switch S2 is turned
into star connection for 400 V.
In this position the transformer is
connected to
the primary pin 7 (red
line).
Three
of
the
motor
wires
are
connected in a star point (thick purple
line). The burner motor and ignition
transformer are connected to this star
point and therefore supplied with 230 V
only.
The machine is set for 230 V but
supply is 400 V. The motor windings
which are made for 230 V are now fed
with 400 V.
The burner motor and the ignition
transformer are now fed with 400 V.
Worst case:
53.
Before connecting devices with voltage changeover:
Check
that
the
pre-selected
voltage
on
the
machine
corresponds with the voltage of the electrical installation.
Otherwise the electrical devices of the machine can be
destroyed!
?
Caution!
?? 230 V / 400 V ??
Star / delta switch S2 is located on the backside of the electrical box
and easy to adjust with a slotted screwdriver.