Neptune_GB_Ver.2.0 10/03
_
6.
Service / Repair
4 mm
5 mm
4,5 mm
Spring washer
Seal
Electrodes / tank meter
7
6
8
13
21
22
4
5
9
10
12
14
11
17
19
18
20
The flame sensor (9) must be
fixed with a screw (5) in the
right
position.
Check and clean the glass (8).
Don’t
over-
tighten!
To insert and remove tank
meter,
carefully
pull
back
suction pipe (don’t bend it!).
Float
switch
moves
from
point A to B (Pic. 6.28). Also
make sure to pull back the
cable of the float switch. Now
insert / remove the whole
unit. Don’t forget to bring
back float switch to operating
position (A) after and make
sure that the seal is in place.
45.
Pic.
:
Electrodes &
fuel nozzle
6.26
Pic.
:
Electrodes & fuel nozzle
6.27
Suction pipe
A
B
Pic. 6.28:
Tank meter &
fuel float switch
How to handle the burner insert:
- Always remove electordes (18) first while
dismounting burner insert.
- Tighten fuel nozzle (17) only with a
hexagonal wrench and a torque of 18 Nm.
Otherwise the fuel nozzle can be damaged
and a proper combustion can’t be
guarantied.
- Always measure the electrode (18) set-up
first and re-adjust if necessary before re-
installing burner insert (values see Pic.
6.26 and 6.27).
A
B
Содержание Neptune 5
Страница 1: ...NEPTUNE 5 NEPTUNE 7 Service Manual...