Neptune_GB_Ver.2.0_10/03
7.
Adjustment / Test
Electronic setup
47.
Service interval setting.
Bridge 3 and 5 on X2 while
changing service interval with the
temperature
adjustment
knob
(100 to 600 hours). Change to
hotwater mode to set new setting.
Pic. 7.1:
Detail of PCB A1
Machine cut off with pressure release.
Function used in connection with remote mode. If “2” is on, machine
switches off after 20 min. in by-pass mode. A restart is only possible with
mainswitch S1. At the same time the ouput of the optional valve Y2 gets
power for 10 s to release pressure at the HP outlet.
Change temperature display.
When “1” is on it shows temperature in
Fahrenheit on
display (NB: it’s not possible to cancel by-pass time when
temp. display is set to Fahrenheit).
°
°
Cancel by-pass time.
Jumper on X10 eliminates by-
pass time of 20 s, which is
necessary
when
adjusting
microswitch B4.
Hour display setting.
Jumper between 2/3 on X9 shows the
total running hours for 5 s on the
display during start-up.
Содержание Neptune 5