Neptune_GB_Ver.2.0_10/03
3.
Construction
A1
B8
B9
S1
A2
12
S1
1a
1
2a
2
T1
Q
A1
A2
K1
A1
A2
K2
1
3
5
2
4
6
PE
L2 L3
L1
Y1
B2
B3
11
7
4
14
13
12
8V AC
24V AC
400V AC
F1
F2
5V DC
µP
X1a
X1b
Datalogger
X2
P
B6
B4
B1
B7
X5-13
X5-15
X4-21
X4-23
X4-17
X4-19
X4-15
X4-13
X4-11
X3-1
X3-9
X3-5
X4-7
X4-1
X4-3
X3-7
X3-3
X3-11
X7
Remote
4
4a
Temp.
Display
Operation
Fuel
Pump Oil
Service
Anti Stone
X5-5
X5-9
X6-9
X5-1
X6-1
X6-6
X6-7
X6-3
X5-3
X6-11
X5-11
X5-7
X4-9
X4-5
~
+
U2 V2 W2
M
3~
V1 W1
U1
M1
F11
13
14
11
14, 24
8
6
5
4
1
2
3
X11
MT
Xma
Xmb
9
7
Xma
Xmb
T2
M
1~
M2
ON
1
2
X7: remote
B8
B4
B6
B1
B9
S1
B7
K1
K2
Y2
Y1
B2
MT
B3
24V
8V
Electric system
K1
K2
Fuse F2
Fuse F1
X2: datalogger
X1a: display
Transformer T1
The electric control system is built up around the control board A1 (Pic. 3.10) which is divided
into two systems, a 5 VDC system on one side to supply the sensors B8, B4, B6, B1, B9, B7 and
on the other side 24 VAC, which supplies the actors (contactor, relay, solenoid valve).
The transformer T1 (Pic. 3.9) supplies the system with 24 VAC and 8 VAC.
13.
Fuse F11
More details about all sensors and the electrical system see page 22 / 23.
Pic. 3.10:
PCB A1
Pic. 3.9:
Electrical box
Содержание Neptune 5