MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual
Installation
Installation Codes and Standards
The following codes and standards are required
for installation of this appliance: air supply,
electrical connections, water connections, and waste
water discharge.
NOTICE:
Where automatically operated appliances are
vented through a ventilating hood or exhaust
system equipped with a damper or with a power
means of exhaust, provisions shall be made
to allow the equipment to operate only when
the damper is open to a position to properly
vent the appliance and when the power means
of exhaust is in operation. IN ACCORDANCE
WITH NFPA 54 COMMONWEALTH OF
MASSACHUSETTS ONLY.
Ventilation Requirements (does not apply to
CTX4-10EVH)
A steam ventilation hood is mandatory for the operation
of the appliance. Authorities having jurisdiction should
be consulted as to the requirements for this equipment
with respect to ventilation and fire extinguishing systems
to ensure conformity with any Federal, State, or local
installation codes.
Microphone Position
Sound Pressure Level dBA
With ventless
hood system
operating
With ventless
hood system
not operating
Front
63.8
59
Right Side
67.5
58
Left Side
69.2
60
Rear
71.9
60
Sound Pressure Measurement
WARNING
Improper installation, alteration, adjustment, service,
cleaning, or maintenance could result in property
damage, severe injury, or death.
Read and understand the installation, operating and
maintenance instructions thoroughly before installing,
servicing, or operating this equipment.