24
MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual
Dimensions
WATER REQUIREMENTS
WATER QUALITY STANDARDS
THREE (3) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4
"
G-style
TWO (2) UNTREATED WATER INLETS: (1) 3/4
"
G-style; (1) 3/4
"
GHT for hand-held sprayer
LINE PRESSURE: 30 psi minimum dynamic and 90 psi maximum static (200 to 600 kPa)
WATER DRAIN:
1-1/2" (
40mm
)
CONNECTION
WITH
A
VERTICAL
VENT
TO
EXTEND
ABOVE
THE
EXHAUST
VENT
.
MATERIALS
MUST
WITHSTAND
TEMPERATURES
UP
TO
200°F (93°C).
CLEARANCE REQUIREMENTS
LEFT:
16-1/4" (413mm)
FOR HOOD FILTER SERVICE
18" (457mm)
RECOMMENDED SERVICE ACCESS
RIGHT: 4" (102mm)
NON-COMBUSTIBLE SURFACES
TOP: 20" (508mm)
FOR AIR MOVEMENT
REAR: 4" (102mm)
BOTTOM: 4" (102mm)
FOR AIR MOVEMENT
INSTALLATION REQUIREMENTS
• Appliance must be installed level.
• Water supply shut-off valve and back-flow preventer when required by local code.
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and if
required, a means of “water treatment” provided that would meet compliance
requirements with the published water quality standards shown below.
Non-compliance with these minimum standards will potentially damage this
equipment and/or components and void the original equipment manufacturer’s
warranty. Alto-Shaam recommends using OptiPure
®
[www.optipurewater.com]
products to properly treat your water.
Contaminant
Free Chlorine
Hardness
Chloride
pH
Silica
Total Dissolved Solids (tds)
Inlet Water Requirements
Less than 0.1 ppm (mg/L)
30–70 ppm
Less than 30 ppm (mg/L)
7.0 to 8.5
Less than 12 ppm (mg/L)
50–125 ppm
DIMENSIONS:
H x W x D
EXTERIOR:
45-7/16" x 20-1/2" x 39-5/16" (1155mm x 519mm x 998mm)
EXTERIOR WITH HAND-HELD SPRAYER:
45-7/16" x 23-3/8" x 39-5/16" (1155mm x 594mm x 998mm)
ELECTRICAL
(DEDICATED CIRCUIT REQUIRED)
✎
GROUND
FAULT
OR
RESIDUAL
CURRENT
PROTECTION
DEVICE
MUST
ACCOMMODATE
A
LEAKAGE
CURRENT
OF
20
m
A
MODEL
VOLTAGE
PH
HZ
AMPS
kW
AWG
CORD & PLUG
CTX4-10EVH
208
1
60
23.4
4.87
—
NEMA L6-30P - US
ONLY
240
1
60
26.3
6.31
8
NO
CORD
OR
PLUG
208 – 240
3
60
15.9 – 18.8
5.59 – 7.67
10
NO
CORD
OR
PLUG
208 – 240
1
60
23.4
–
26.3
4.87 – 6.31
—
8/3
CORD
,
NO
PLUG
220 – 240
1
50/60
24.9
– 26.3
5.47 – 6.60
8
NO
CORD
OR
PLUG
380 – 415
3
50/60
9.8 – 10.8
6.49 – 7.67
10
NO
CORD
OR
PLUG
WEIGHT
PAN CAPACITY
STANDARD MODEL
NET
260 lbs
EST
118 kg
FULL–SIZE:
20" x 12" x 2-1/2"
Five (5)
GN 1/1:
530 x 325 x 65mm
Five (5)
SHIP
415
lbs*
188 kg*
GN 1/1:
530 x 325 x 20mm
Ten (10)
**HALF–SIZE SHEET:
18" x 13" x 1"
Ten (10)
SHIP DIMENSIONS
PRODUCT CAPACITY
(L x W x H) 43" x 31" x 58"*
PRODUCT MAXIMUM
48 lb (22 kg)
(1092 x 787 x 1473mm)*
VOLUME MAXIMUM
30 quarts (38 liters)
*
DOMESTIC
GROUND
SHIPPING
INFORMATION
.
CONTACT
FACTORY
FOR
EXPORT
WEIGHT
AND
DIMENSIONS
.
**
ON
WIRE
SHELVES
ONLY
.
ADDITIONAL
WIRE
SHELVES
REQUIRED
FOR
MAXIMUM
CAPACITY
✎
15-3/4"
(401mm)
CAVITY
25-3/8"
(644mm)
CAVITY
16-7/16"
(417mm)
39-7/16" (1002mm)
EXHAUST VENT
31"
(787mm)
15-5/8"
(396mm)
16-1/4"
(413mm)
CAVITY
9-1/4" (234mm)
20-3/4" (527mm)
30-1/8" (765mm)
39-3/8" (999mm)
4-5/8" (118mm)
2-1/2"
(64mm)
A: TETHER BRACKET REQUIRED FOR 380-415V,
CASTER STAND, OR STACKING KITS
B: TREATED WATER INLET
C: UNTREATED WATER INLET
D: 1-1/2" (38mm) DRAIN
E: TANK CLEAN-OUT
F: ELECTRICAL CONNECTION - CORD OR HARDWIRE
4-3/4" (120mm)
5-3/4" (145mm)
6" (152mm)
8-1/4" (210mm)
11-1/2"
(290mm)
27"
(686mm)
7-15/16"
(201mm)
5-15/16"
(150mm)
17-11/16" (449mm)
15" (379mm)
11-11/16"
(296mm)
HAND SPRAYER
VALVE REQUIRES
SEPARATE WATER
CONNECTION
23-3/8" (593mm)
3/4" (18mm)
2-1/8"
(54mm)
39-3/8"
(999mm)
4"
(102mm)
45-1/2"
(1155mm)
17-3/8" (442mm)
24-1/8" (611mm)
LEFT HINGE DOOR
RIGHT HINGE DOOR
C
E
D
B
F
A
C
E
D
B
F
CTX4-10EVH