MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual
25
Dimensions
ELECTRICAL
(DEDICATED CIRCUIT REQUIRED)
✎
GROUND
FAULT
OR
RESIDUAL
CURRENT
PROTECTION
DEVICE
MUST
ACCOMMODATE
A
LEAKAGE
CURRENT
OF
20
m
A
MODEL
VOLTAGE
PH
HZ
AMPS
kW
AWG
CORD & PLUG
CTX4-10EC
208
1
60
23.6
4.91
—
NEMA L6-30P - US
ONLY
240
1
60
26.6
6.38
8
NO
CORD
OR
PLUG
208 – 240
3
60
16.1– 19.1
5.63 – 7.75
10
NO
CORD
OR
PLUG
208 – 240
1
60
23.6
–
26.6
4.91 – 6.38
—
8/3
CORD
,
NO
PLUG
220 – 240
1
50/60
25.1
– 26.6
5.53 – 6.66
8
NO
CORD
OR
PLUG
380 – 415
3
50/60
11.1 – 12.3
6.53 – 7.75
10
NO
CORD
OR
PLUG
WEIGHT
PAN CAPACITY
STANDARD MODEL
NET
180 lbs
EST
82 kg
FULL–SIZE:
20" x 12" x 2-1/2"
Five (5)
†
GN 1/1:
530 x 325 x 65mm
Five (5)
†
SHIP
310
lbs*
141 kg*
GN 1/1:
530 x 325 x 20mm
Ten (10)
†
**HALF–SIZE SHEET:
18" x 13" x 1"
Ten (10)
†
SHIP DIMENSIONS
PRODUCT CAPACITY
(L x W x H) 37" x 42" x 45"*
PRODUCT MAXIMUM
48 lb (22 kg)
(940 x 1067 x 1143mm)*
VOLUME MAXIMUM
30 quarts (38 liters)
*
DOMESTIC
GROUND
SHIPPING
INFORMATION
.
CONTACT
FACTORY
FOR
EXPORT
WEIGHT
AND
DIMENSIONS
.
**
ON
WIRE
SHELVES
ONLY
.
ADDITIONAL
WIRE
SHELVES
REQUIRED
FOR
MAXIMUM
CAPACITY
†
CAPACITY
WITHOUT
BROILER
ELEMENT
OPTION
✎
15-3/4" (401mm)
CAVITY
18-3/4" (476mm)
3-1/16"
(77mm)
37-3/16
" (945mm)
35-11/16
" (907mm)
16-7/16
" (471mm)
39-3/8" (1000mm)
3-1/8
" (80mm)
EXHAUST VENT
25-7/16
" (646mm)
CA
VITY
1-11/16" (43mm)
HAND SPRAYER
VALVE REQUIRES
SEPARATE WATER
CONNECTION
3/4
" (18mm)
1-3/4
" (44mm)
2"
(50mm)
5-3/16" (132mm)
7-3/16" (182mm)
10-15/16"
(278mm)
14-3/16" (360mm)
16-15/16" (430mm)
4-5/16
" (109mm)
7-7/16
" (189mm)
23
" (584mm)
A
B
C
D
E
F
G
A: HI-LIMIT RESET
B: TETHER BRACKET REQUIRED FOR 380-415V, CASTER
STAND, OR STACKING KITS
C: TREATED WATER INLET
D: UNTREATED WATER INLET
E: 1-1/2" (38mm) DRAIN
F: TANK CLEAN-OUT
G: ELECTRICAL CONNECTION - CORD OR HARDWIRE
LEFT HINGE DOOR
20-3/8" (517mm)
33-7/16
" (850mm)
20-7/8
" (531mm)
4"
(102mm)
17-3/8" (442mm)
3" (76mm)
23-3/8" (593mm)
29-5/8" (753mm)
TOP SURFACE
15-5/8
" (396mm)
16-1/4
" (413mm)
CA
VITY
2-1/2"
(64mm)
5-7/8" (150mm)
20-3/4" (527mm)
31-5/8" (803mm)
RIGHT HINGE DOOR
DIMENSIONS:
H x W x D
EXTERIOR:
33-7/16" x 20-3/8" x 37-3/16" (850mm x 517mm x 945mm)
EXTERIOR WITH HAND-HELD SPRAYER:
33-7/16" x 23-3/8" x 37-3/16" (850mm x 593mm x 945mm)
WATER REQUIREMENTS
WATER QUALITY STANDARDS
THREE (3) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: (1) 3/4
"
G-style
TWO (2) UNTREATED WATER INLET: (1) 3/4
"
G-style; (1) 3/4
"
GHT for hand-held sprayer
LINE PRESSURE: 30 psi minimum dynamic and 90 psi maximum static (200 to 600 kPa)
WATER DRAIN:
1-1/2" (
40mm
)
CONNECTION
WITH
A
VERTICAL
VENT
TO
EXTEND
ABOVE
THE
EXHAUST
VENT
.
MATERIALS
MUST
WITHSTAND
TEMPERATURES
UP
TO
200°F (93°C).
CLEARANCE REQUIREMENTS
LEFT: 4" (102mm)
18" (457mm)
RECOMMENDED SERVICE ACCESS
RIGHT: 4" (102mm)
NON-COMBUSTIBLE SURFACES
TOP: 20" (508mm)
FOR AIR MOVEMENT
REAR: 4" (102mm)
BOTTOM: 4" (102mm)
FOR AIR MOVEMENT
INSTALLATION REQUIREMENTS
• Appliance must be installed level.
• Water supply shut-off valve and back-flow preventer when required by local code.
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and if
required, a means of “water treatment” provided that would meet compliance
requirements with the published water quality standards shown below.
Non-compliance with these minimum standards will potentially damage this
equipment and/or components and void the original equipment manufacturer’s
warranty. Alto-Shaam recommends using OptiPure
®
[www.optipurewater.com]
products to properly treat your water.
Contaminant
Free Chlorine
Hardness
Chloride
pH
Silica
Total Dissolved Solids (tds)
Inlet Water Requirements
Less than 0.1 ppm (mg/L)
30–70 ppm
Less than 30 ppm (mg/L)
7.0 to 8.5
Less than 12 ppm (mg/L)
50–125 ppm
CTX4-10EC