MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual
41
Service
Continued on next page
Error
Code
Error Call Out in Display
Description of Error
Possible Causes
E01
Low Water Boiler
Low water level in boiler
— Water supply is shut off .
— Low water pressure.
— Generator drain cap/hose missing or leaking.
— Generator drain pump is defective.
— Generator drain pump elbow leaking.
— Fill solenoid not energized.
— Fill solenoid faulty.
— Wiring or connection error at the solenoid or the relay board.
— Water level probe connection/wiring error at probe or relay board.
— Water level probe requires descaling and/or replacement.
E02
Control Temperature High
Relay board surface
temperature too high
— Cooling fan(s) not being energized.
— Cooling fan(s) faulty.
— Wiring/connection error at cooling fan(s).
— Faulty relay board.
E03
Convection Fan Motor Error
Convection fan
motor failure
— Motor VFD not energized.
— No input signal to VFD from relay board.
— Motor VFD faulty, not outputting to motor aft er input signal
received.
— Motor fan wheel blocked/obstructed.
— Connection/wiring error at VFD, motor, hall eff ect sensor,
relay board.
— Faulty motor.
E04
Lower Convection Fan
Motor Error
Lower convection fan motor
failure on 20-20 unit
— Motor VFD not energized.
— No input signal to VFD from relay board.
— Motor VFD faulty, not outputting to motor aft er input
signal received.
— Motor fan wheel blocked/obstructed.
— Connection/wiring error at VFD, motor, hall eff ect sensor,
relay board.
— Faulty motor.
When the appliance malfunctions, an error code will appear in the display.
Press the Start icon to acknowledge the error.
When the appliance error notifi cation has been acknowledged, the appliance will attempt to return to normal operation.
NOTICE
This section is provided for the assistance of qualified and trained service technicians only and is not intended for
use by untrained or unauthorized service personnel. Do not attempt to repair or service the appliance beyond this
point. Contact Alto-Shaam for the nearest authorized service agent. Repairs made by any other service agents without
prior authorization by Alto-Shaam will void the warranty.
Error Codes
If the Alto-Shaam® unit is not operating properly, check the following before calling an Authorized Alto-Shaam
Service Agent:
▶ Check that the appliance is receiving power. Is the circuit breaker turned on?