# 6 0 0 1
C O M B I T H E R M E L E C T R I C I N S TA L L AT I O N A N D M A I N T E N A N C E M A N U A L
P G
. 3
B A S I C I N S TA L L AT I O N S I T E R E Q U I R E M E N T S
H O O D I N S T A L L A T I O N I S R E Q U I R E D
• Installation surface must be level.
• Do not install adjacent to flammable surfaces.
• Deep fat fryers or similar heat producing
equipment must not be installed in the
immediate vicinity of the hand shower.
The oven must remain on the pallet while being moved
to the installation site with fork lift or pallet lift truck.
D o n o t t i l t t h e o v e n .
V E N T I L AT I O N R E Q U I R E M E N T S
A steam ventilation hood is mandatory for the operation of the oven. The ventilation hood must be installed
in accordance with local building codes for steam exhaust and must protrude 12-inches to 20-inches
(300mm to 500mm) over the front side of the oven. A grease filter must be located in the protruding area of
the hood. Grease filters should be thoroughly cleaned on a regular basis following manufacturer's
instructions. Ventilation hoods must ensure an adequate amount of incoming air during operation and must
be operated whenever the combination oven/steamer is used in order to avoid the accumulation of
condensation in the hood area.
Where automatically operated appliances are vented through a ventilating hood or exhaust
system equipped with a damper or with a power means of exhaust, provisions shall be made
to allow the equipment to operate only when the damper is open to a position to properly
vent the appliance and when the power means of exhaust is in operation.
IN ACCORDANCE WITH
NFPA 54
COMMONWEALTH OF MASSACHUSETTS ONLY
.
If a ventless hood is to be installed, we
recommend the Combitherm Ventless Hood for the
appropriate model oven. Ventless hoods are
available for the Combitherm models
6•10, 7•14, 10•10, and 10•18 (VH
ML
-10) electric.
MODEL
V H
M L
- 1 0
Air Movement
1200
CFM
Drain Connection
3/4" (19,1mm) NPT
Electrical
208-240 V.A.C. — 50/60 Hz, 1 ph
240 watts, 1.0 amps
Ship Weight
126 lb (57 kg)
Replacement
Filters
GREASE
FI-23062
CHARCOAL
FI-24102
C O M B I T H E R M
®
I N S TA L L AT I O N
N
O
T
E
DO NOT store or use any flammable
liquids or allow flammable vapors
in the vicinity of any appliance.
Содержание 10-10ML
Страница 17: ......
Страница 48: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 46...
Страница 49: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 47...
Страница 50: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 48...
Страница 51: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 49...