C O M B I T H E R M E L E C T R I C I N S TA L L AT I O N A N D M A I N T E N A N C E M A N U A L
P G
. 3 3
T RO U B L E S H O OT I N G
CODE
E15
E21
E22
E23
E24
E25
E26
E27
E29
E33
E34
E80
E81
E82
E83
E96
DESCRIPTION OF ERROR
Condenser probe (B3 thermocouple) measures a temperature
in excess of 212°F (100°C).
Oven temperature probe (N6) is interrupted.
Core temperature probe (B10) is interrupted.
Steam generator probe (B4 thermocouple) is interrupted.
Stem Bypass probe (B5) is interrupted.
Condensate probe (B3 thermocouple) is interrupted.
Safety temperature probe (N8 thermocouple) is interrupted.
STB (N8 thermocouple) measures a temperature in excess of
266°F (130°C).
Thermocouple shorted to ground.
Steam generator probe (B3) fails to measure increase in
temperature to 41°F (5°C) within a 3 minute period of time.
Steam generator pump malfunction.
ID (identity) error.
Cooking procedure-programming error.
Preset program or cleaning program has become corrupt.
Communication problem between display and relay board.
Incompatibility between software and hardware.
POSSIBLE CAUSE/REMEDY
Water tap is closed.
Oven is connected to warm water supply.
Inlet filter on solenoid valve is dirty.
Condenser cooling solenoid valve or solenoid valve coil (Y2)
is defective.
Probe connection is loose or defective at X6
Probe connection is loose or defective at X6
Probe connection is loose at X6 on the control module.
Steam generator probe (B4) is defective.
Bad probe connection.
Probe connection is loose or defective at X6
Probe connection is loose or interrupted at X6
Probe is defective.
Probe connection is loose at X6 on the control module.
STB steam generator probe (N8) is interrupted or defective.
Immersion element safety thermostat (N8) is tripped.
Calcification on steam elements
Water level probe is grounded causing immersion elements
to energize.
Water softener causing bubbles in the steam generator.
Check all thermocouple probes to ground.
Immersion element safety thermostat N8 tripped.
Immersion element contactors K1, K2, K3 defective.
B4 probe calcified.
Pump (M4) defective.
Drain valve blocked or drain clogged.
Ground short on water level probe due to calcification.
Fill opening in water settling area of level probe is calcified.
The electronic control cannot differentiate between gas or
electric operation and disconnects all circuit connections.
Contact problem on X3 connection.
Unit has been changed from Fahrenheit to Celsius.
The sequence must be deleted and reprogrammed.
Press and hold the Chef function key while in the OFF mode
and verify both the BM and SM software versions.
Communications cable is lose between relay board and
display board.
Communications cable defective.
Alto-Shaam has established a twenty-four hour emergency service
call center to offer immediate customer access to a local authorized
service agency outside of standard business hours. The emergency
service access is provided exclusively for Alto-Shaam equipment
and is available throughout the United States through the use of
Alto-Shaam's toll-free number. Emergency service access is
available seven days a week including holidays
.
Содержание 10-10ML
Страница 17: ......
Страница 48: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 46...
Страница 49: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 47...
Страница 50: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 48...
Страница 51: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 49...