# 6 0 0 1
C O M B I T H E R M E L E C T R I C I N S TA L L AT I O N A N D M A I N T E N A N C E M A N U A L
P G
. 2 7
TURN THE SELECTION KNOB TO THE STEAM POSITION.
THE WATER IN THE STEAM GENERATOR WILL BEGIN TO HEAT. ALLOW THE OVEN TO REMAIN IN
THIS POSITION FOR A MINIMUM PERIOD OF 10 MINUTES TO DECALCIFY THE STEAM GENERATOR.
DO NOT
TURN THE TIMER ON. Severe burns could occur.
C H E F O P E R AT I N G T I P
I n t h e c a s e o f e x t r e m e c a l c i f i c a t i o n b u i l d - u p s u c h a s i n a r e a s w i t h v e r y
h a r d w a t e r, o v e n s c a n b e l e f t i n t h i s c o n d i t i o n o v e r n i g h t . F o l l o w t h e
r e m a i n i n g i n s t r u c t i o n s a t t h e s t a r t o f t h e n e x t p r o d u c t i o n d a y . T h i s
p r o c e d u r e w i l l h e l p k e e p t h e o v e n o p e r a t i n g a t p e a k e f f i c i e n c y .
After a period of 10 minutes or longer —
TURN THE SELECTION KNOB TO THE
OFF
POSITION.
6.
USING HAND PROTECTION
, open the oven door and rotate the Steam Generator Drain Cap
until
water begins to flow from the four holes in the cap. In approximately 20 to 60 seconds, a sufficient
quantity of water will have drained from the steam generator so that the drain cap can be completely
removed. Let the water continue to drain until the flow completely subsides.
7.
Loosen the thumb screw(s) and swing Fan Guard Cover Plate
toward the back of the oven. Using the
hand-held hose, direct a stream of water directly into the Steam Exit Port
several times. Close the
swing-out Cover Plate
. Lock the cover into place and tighten thumb screw(s). Close the oven door.
TURN THE SELECTION KNOB TO THE
STEAM
POSITION.
A new supply of fresh water will begin to fill the steam generator and will flush out
all remaining vinegar from the steam generator.
AFTER
JUST 2 MINUTES
OF OPERATION IN THE STEAM MODE, TURN THE SELECTION KNOB
TO THE
OFF
POSITION.
ANY ADDITIONAL LENGTH OF TIME WILL RESULT IN A LOW WATER ERROR OCCURRENCE.
OPEN THE OVEN DOOR.
8.
USING HAND PROTECTION
, replace the Steam Generator Drain Cap by turning it clockwise until
there is a slight resistance. At the end of the production day, leave the door slightly ajar.
DO NOT
COOK IN ANY PROGRAM MODE
WITH VINEGAR IN THE STEAM GENERATOR SYSTEM.
DURING DECALCIFICATION THE WATER FLOWING FROM THE DRAIN CAP IS
EXTREMELY HOT! USE HAND PROTECTION WHEN TOUCHING THE STEAM
GENERATOR DRAIN CAP. DO NOT TOUCH THE WATER FLOWING OUT OF
THE STEAM GENERATOR DRAIN CAP OR STEAM GENERATOR DRAIN.
C O N T R O L
O P T I O N
C O M B I T H E R M
®
D E C A L C I F I C AT I O N
Содержание 10-10ML
Страница 17: ......
Страница 48: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 46...
Страница 49: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 47...
Страница 50: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 48...
Страница 51: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 49...