WATER DRAINAGE
The oven must discharge through an
indirect waste pipe by means of an air gap.
The drain thread is 1-1/4-inch (32mm) NPT.
A union is required. Install a 1-1/4-inch
(32mm) diameter drain line. The drain line
must always be a positive gradient away
from the Combitherm oven and not more than
12-inches (305mm) before an air gap.
NOTE:
In the U.S.A., this equipment is to be
installed to comply with the Basic
Plumbing Code of the Building
Officials and Code Administrators
International, Inc. [BOCA], and the
Food Service Sanitation Manual of the
Food & Drug Administration [FDA].
If several units are to be connected to one
drain pipe, the dimensions of the pipe must
be sufficient to allow an unobstructed water
drain system.
AVERAGE DRAIN WATER TEMPERATURE
149°F (65°C)
1-1/4" (32mm) diameter NPT
WASTE PIPE
1-1/2" to 2" minimum diameter
(c. 38mm to 51mm)
2" (51mm)
Air Gap