# 6 0 0 1
C O M B I T H E R M E L E C T R I C I N S TA L L AT I O N A N D M A I N T E N A N C E M A N U A L
P G
. 3 1
E M E R G E N C Y O P E R AT I O N
In the event of an error code, operation of the Combitherm can be continued on a limited basis for a short
duration. Cooking times may be longer than normal operation and close monitoring of the cooking
process is recommended. Contact an authorized service agency immediately if the problem cannot be
rectified with simple steps in the troubleshooting guidelines located in this manual. Error conditions
under which continued operation can be conducted are indicated by
YES
in the chart shown below.
When the oven malfunctions, an error code will appear in the display.
PRESS THE START/STOP KEY TO ACKNOWLEDGE THE ERROR.
The keys for the usable operational modes will begin to flash and can be operated normally.
SELECT AND PRESS ONE OF THE COOKING MODES INDICATED.
The oven control will only respond to the oven mode keys flashing.
SET THE OVEN CONTROLS AS IF OPERATING UNDER NORMAL CIRCUMSTANCES.
Depending on the error code involved, oven function, such as temperature range, may be limited.
PRESS THE START/STOP KEY TO BEGIN THE COOKING PROCESS.
PRESS THE START/STOP KEY WHEN THE TIMER EXPIRES.
WHEN THE OVEN FAULT IS CORRECTED, THE COMBITHERM WILL RETURN TO NORMAL OPERATION.
1
Cooking time increases significantly. Food on the upper shelves is finished first.
2
Water injection into the condenser is activated for the entire cooking mode (high water consumption).
3
When error codes E23 and E26 appear simultaneously, steam generator does not preheat.
ERROR
DISPLAY MESSAGE
GAS
ELECTRIC
STEAM
1
SUPERHEATED
CONVECTION
RETHERM
DELTA
-
T
CODE
MODE
STEAM MODE
MODE
MODE
MODE
E01
Low water level
YES
YES
NO
NO
up to 356°F
NO
YES
(180°C)
E02
EL-temperature too high
YES
YES
YES
Up to 284°F
Up to 284°F
Up to 284°F
Up to 284°F
CONTROL COMPARTMENT TEMP
(140°C)
(140°C)
(140°C)
(140°C)
E03
Fan Fault
NO
YES
Up to 212°F
NO
NO
NO
NO
BLOWER FAN
(100°C)
E04
EL-fan fault
NO
YES
YES
Up to 284°F
Up to 284°F
Up to 284°F
Up to 284°F
CONTROL COOLING FAN
(140°C)
(140°C)
(140°C)
(140°C)
E05
Gas fault
YES
NO
YES
YES
YES
YES
YES
E15
Condenser oven temperature
YES
YES
NO
NO
Up to 356°F
NO
YES
HIGH CONDENSATE TANK TEMP
(180°C)
E21
Oven probe error
NO
YES
212°F only
NO
NO
NO
NO
TEMPERATURE PROBE
(100°C)
E22
CTC error
TEMPERATURE PROBE
YES
YES
YES
YES
YES
YES
YES
E23
SG-probe error
YES
YES
YES
YES
YES
YES
YES
STEAM GENERATOR PROBE
B4
E24
Bypass probe error
NO
YES
Up to 210°F
NO
YES
NO
YES
(99°C)
E25
Condenser probe error
NO
YES
YES
2
Up to 356°F
2
Up to 356°F
2
Up to 356°F
2
YES
2
B3
PROBE
(180°C)
(180°C)
(180°C)
E26
SG probe error
NO
YES
YES
YES
YES
YES
YES
STEAM GENERATOR PROBE
E23 &
SG probe error
3
NO
YES
YES
3
YES
3
YES
3
NO
YES
3
E26
STEAM GENERATOR PROBE
B4
E33
SG heat error
NO
YES
YES
YES
YES
YES
YES
STEAM GENERATOR ELEMENT
E34
Steam Generator pump error
NO
YES
YES
YES
YES
YES
YES
E81
Program memory error
YES
YES
YES
YES
YES
YES
YES
E83
Algorithm error
YES
YES
YES
YES
YES
YES
YES
E89
12C error
YES
YES
YES
YES
YES
YES
YES
Содержание 10-10ML
Страница 17: ......
Страница 48: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 46...
Страница 49: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 47...
Страница 50: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 48...
Страница 51: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 49...