# 6 0 0 1
C O M B I T H E R M E L E C T R I C I N S TA L L AT I O N A N D M A I N T E N A N C E M A N U A L
P G
. 7
WATER SUPPLY
C O N N E C T TO P OTA B L E (
D R I N K A B L E
) C O L D WAT E R O N LY
WAT E R P R E S S U R E R E Q U I R E M E N T S
:
M I N I M U M
3 0 P S I ( 2 B A R )
MAXIMUM
9 0 P S I ( 6 B A R )
Flush the water line at the installation site before connecting the oven to the water supply. A shut-off valve and
approved back-flow preventer must be installed when connecting the oven to the cold water intake. The water
supply line must be a minimum of 3/4-inch (NPT) (19mm). A hose connector is supplied for flexible hose
connection to the
COLD
water source. Connected water should test at hardness level of 5 to 9 grains per gallon
(85 to 154 ppm). A water filtration system is recommended if the water supply is between 5 and 9 gpg of
hardness. If water tests over 18 gpg of hardness (344 ppm), the
installation of a water softener to maintain oven function is strongly
recommended.
PIPE SEALING TAPE
(
TEFLON
®
)
MUST BE USED
AT ALL CONNECTION POINTS.
The use of a pipe sealing compound is not recommended.
THE SHUT-OFF VALVE MUST BE IN THE OPEN POSITION
WHEN THE OVEN IS BEING USED.
The hand shower spray hose is installed adjacent
to the cold water intake connection. A ball valve
is installed on the oven for hose connection to the
COLD
water source. Assemble the washer and
the flexible hose on the ball valve and hang the
spray handle on the holder previously installed
on the oven.
Alto-Shaam now offers an improved water filtration system for
Combitherm®. The CombiGuard™ triple-guard water filtration
system filters dirt, sediment, and other debris as small as 1/2
micron. This system also significantly reduces chlorine content to
protect against corrosive chlorine compounds. CombiGuard
improves equipment efficiency, reduces service requirements and
extends the life of the Combitherm. Filtration system includes one
filter cartridge. Additional cartridges
(
FI-26356)
can be
purchased separately.
C O M B I T H E R M
®
I N S TA L L AT I O N
ELBOW
WATER
COLD WATER — DRINKING QUALITY
INDIRECT WASTE PIPE WITH AIR GAP
:
1-1/2"
NPT
INLET
:
3/4"
NPT
LINE PRESSURE
:
30 to 90 psi
2 to 6 bar
CHLORINE
:
less than 0.8 ppm
CHLORIDE
:
less than 70 ppm
HARDNESS
:
5 to 9 gpg
PH R ANGE
:
7.0 to 9.0
85 to 154 ppm
WATER SOFTENER SHOULD BE UTILIZED
IN HARD WATER AREAS
.
ITEM
FI-23014
Содержание 10-10ML
Страница 17: ......
Страница 48: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 46...
Страница 49: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 47...
Страница 50: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 48...
Страница 51: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 49...