C O M B I T H E R M E L E C T R I C I N S TA L L AT I O N A N D M A I N T E N A N C E M A N U A L
P G
. 9
C O M B I T H E R M
®
I N S TA L L AT I O N
STACKING INSTALLATION
Stacking Combitherm ovens require two (2) water connections, two (2) drain connections, and two (2)
electrical connections.
I f l o c a l c o d e a l l o w s
,
the water and drain may
be manifolded as long
as the size of the water
inlet is increased to
1-inch (25,4mm) and
the drains include an
external vent. The
drawing illustrates
one suggested
method of a
manifold
installation.
3/4"
(19mm)
1"
(25,4mm)
UNION
UNION
Intake
1" (25,4mm)
VENT
15" (381mm)
1-1/4"
(32mm)
1-1/2" (38mm)
WATER INTAKE
DRAIN
RESTRAINT REQUIREMENTS — MOBILE EQUIPMENT
Any appliance that is not furnished with a power supply
cord but that includes a set of casters must be provided
with a tether. Adequate means must be provided to limit
the movement of this appliance without depending on or
transmitting stress to the electrical conduit. The
following requirements apply:
1.
Casters must be a maximum height of 6" (152mm).
2.
Two of the casters must of be the locking type.
3.
Such mobile appliances or appliances on mobile stands must be
installed with the use of a flexible connector secured to the
building structure.
A mounting connector for a restraining device is located on the l
ower back flange of the appliance chassis or on an oven stand,
approximately 18" (457mm) from the floor. A flexible connector is
not supplied by nor available from the factory.
RISK OF ELECTRIC SHOCK.
Appliance must be secured
to building structure.
Содержание 10-10ML
Страница 17: ......
Страница 48: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 46...
Страница 49: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 47...
Страница 50: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 48...
Страница 51: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 49...