NOTE 1  At 80MHz and 800MHz, the higher frequency range applies.
NOTE 2  These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and 

reflected from structures, objects and people.

a  Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile 

radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To 

assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. 

If the measured field strength in the location in which the Human Care lifts is are used exceeds the applicable RF compliance 

level above, the Human Care lifts should be observed to verify normal operation. If abnormal performance is observed, 

additional measures may be necessary, such as reorienting or relocating the Human Care lifts.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 10 V/m.

Recommended separation distances between portable and mobile RF communications equipment and the Human Care 

lifts.

The Human Care lifts are intended for use in an electromagnetic environment in which radiated RF disturbances are 

controlled. The customer or the user of the Human Care lifts can help prevent electromagnetic interference by maintaining 

a minimum distance between portable and mobile RF communications equipment (transmitters) and the Human Care lifts as 

recommended below, according to the maximum output power of the communications equipment.

Rated maximum 

output power of 

transmitter

W

Separation distance according to frequency of transmitter 

m

150 kHz to 80 MHz

d = 1,2√P

80 MHz to 800 MHz

d = 1,2√P

800 MHz to 2.5 GHz

d = 0,7√P

0.01

0.12

0.12

0.07

0.1

0,37

0,37

0,22

1

1,16

1,16

0,7

10

3,67

3,67

2,21

100

11.6

11.6

7

For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) 

can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power 

rating of the transmitter in watts (W) according to the transmitter manufacturer. 
Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and 

reflection from structures, objects and people.

 Guidance and manufacturer’s declaration

ENG

Содержание 55030

Страница 1: ...Altair Anv ndarmanual User manual Manuel de l utilisateur Gebruikshandleiding Benutzerhandbuch...

Страница 2: ...raise and lower patients in a vertical direction and never diagonally or through angles The lift must always be positioned directly above the patient when lifting The patient must always be positioned...

Страница 3: ...th Altair Before use always ensure that personnel who use the equipment have been given adequate tuition and training in use of the lift and its accessories the lift belt is not twisted or worn and th...

Страница 4: ...hanical Class Internally powered equipment Type B IP rating lift IPX4 IP rating hand control IPX5 Noise level 65dB loaded and unloaded Lifting speed 1 8 m min 3 0 m min unloaded only Lifting height 20...

Страница 5: ...www humancaregroup com Product description 1 Hand control 2 Lift belt 3 Telescopic bar 4 Leg hook 5 Secondary control panel 6 Emergency lowering button 7 Indicator 8 Emergency stop ENG 1 2 3 8 7 6 5...

Страница 6: ...duct has been tested by an accredited test institute and complies with the necessary requirements in accordance with the Medical Devices Directive for Class 1 products MDD 93 42 EEC The lift is CE mar...

Страница 7: ...falls If the lift belt is pulled out too quickly the safety catch will engage thus preventing the fall Slacken the lift belt to unlock the catch With the safety catch engaged the lever 10 can never be...

Страница 8: ...run at two speeds If the Up or Down button is pressed for longer than 3 seconds the lift will run in the faster mode If the lift is loaded with more than approx 40 kg it will only run in the slower m...

Страница 9: ...USB for communicating with the lift Secondary control panel The lift is equipped with a secondary control panel located on the lift which can be used as an alternative to the hand control It is equipp...

Страница 10: ...level is Low The lift must be charged up immediately Charger The indicator on the lift flashes red when the batteries need recharging Plug the charger cable into the hand control or put the hand cont...

Страница 11: ...patient Press the Down button on the hand control or control panel to lower the patient Pressing the button activates a soft start and releasing it causes a soft stop Lower the lift so that it stands...

Страница 12: ...ve three adjustable positions To change position turn the hooks 1 4 turn while pushing or pulling the hooks to the desired position The hooks will automatically fall into place in the position and so...

Страница 13: ...atient individually and in accordance with their needs Consult the user manual for the relevant sling to make sure the product is used correctly Human Care recommends using only Human Care slings with...

Страница 14: ...or the Down button on the hand control or the control panel Constant yellow Charging in progress Interrupt charging Nothing happens when you press the Up button on the hand control or the control pane...

Страница 15: ...he lift belts for damage or wear and tear Feed out enough of the lift belts to allow Care instructions for the lift and accessories their entire length to be checked Contact a retailer if the belt is...

Страница 16: ...vel Compliance level Electro magnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floor...

Страница 17: ...4 3 3 Vrms 150 kHz to 80 MHz 3 V m 80MHz to 2 5GHz 10 V m 800MHz to 2 5GHz 3 Vrms 3 V m 10V m Portable and mobile RF communications equipment should be used no closer to any part of the Human Care li...

Страница 18: ...e lifts The Human Care lifts are intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Human Care lifts can help prevent e...

Отзывы: