TESTiNG iN-LiNE GFCi UNiT
(Before Each Use Of The Polisher)
•
Connect polisher to a single phase AC power supply.
•
Verify that the indicator lens shows red (indicating output voltage).
•
Press the test button to verify that the red in the indicator lens disappears.
•
Press the reset button to verify the red indicator is visible.
•
The GFCI is now ready for use.
DO NOT USE IF ABOVE TEST FAILS!
VAriABLE SPEED ADJUSTMENT
This polisher is equipped with a Variable Speed control that will allow the spindle
speed to be adjusted from 500 RPM to 2800
RPM. Speed adjustment is controlled by rotation
of the wheel as shown in the Figure 4.
NOTE- Wheel numbers are for reference point
of motor speed (#1 is 500 RPM and #6 is 2800
RPM).
Adjust the RPM of the tool to match the
recommended RPM of the product being used.
WARNING!
I
ndicator viewing lens.
RED lens shows power to
polisher.
CLEAR lens shows no
power
to polisher.
RESET BUTTON
TEST BUTTON
Figure-5
Figure-6
INCREASE SPEED
DECREASE SPEED
Figure-7