31
LWC 80
— ı • ı —
• ı —
•
—
8,6 ı 4,2
—
8,5 ı 3,5
—
8,0 ı 3,5
—
9,1 ı 4,3
—
6,1 ı 2,8
—
—
20¹ – 52²
-20 – 35
A> -7 / 60²
47
46
2500
25
850 ı 1700 ı 2150
— ı —
0,36 ı 1200
55
•
--
295
R1"AG
R1"AG
R407C ı 3,2
570 x 570
30 ı 1
3~/PE/400V/50Hz ı C10
1~/N/PE/230V/50Hz ı B10
3~/N/PE/400V/50Hz ı C10
2,0 ı 4,1 ı 0,7
7,2
46 ı 22
20
6 ı 4 ı 2
0,09 ı n.n.
• ı —
•
—
—
•
• ı 18 ı 1,5
•
•
813090
LWC 100
— ı • ı —
• ı —
•
—
12,2 ı 4,1
—
11,8 ı 3,3
—
10,4 ı 3,4
—
13,1 ı 4,3
—
8,4 ı 2,8
—
—
20¹ – 58² (60²)*)
-20 – 35
—
47
49
3400
25
1200 ı 2000 ı 2500
— ı —
0,5 ı 2000
80
•
1
300
R1"AG
R1"AG
R404A ı 4,1
570 x 570
30 ı 1
3~/PE/400V/50Hz ı C16
1~/N/PE/230V/50Hz ı B10
3~/N/PE/400V/50Hz ı C16
2,9 ı 5,5 ı 0,75
8
62 ı 24
20
9 ı 6 ı 3
0,18 ı n.n.
• ı —
•
—
—
•
• ı 24 ı 1,5
•
•
813083-g
LWC 120
— ı • ı —
• ı —
•
—
13,7 ı 4,2
—
13,5 ı 3,3
—
11,9 ı 3,4
—
14,6 ı 4,4
—
9,5 ı 2,7
—
—
20¹ – 58² (60²)*)
-20 – 35
—
47
49
3400
25
1500 ı 2500 ı 3000
— ı —
0,45 ı 2500
80
•
--
305
R5/4"AG
R5/4"AG
R404A ı 4,5
570 x 570
30 ı 1
3~/PE/400V/50Hz ı C16
1~/N/PE/230V/50Hz ı B10
3~/N/PE/400V/50Hz ı C16
3,3 ı 6,3 ı 0,75
9,7
61 ı 25
20
9 ı 6 ı 3
0,18 ı n.n.
• ı —
•
—
—
•
• ı 24 ı 1,5
•
•
813082-g
LWC 60
— ı • ı —
• ı —
•
—
7,0 ı 4,2
—
6,8 ı 3,5
—
6,2 ı 3,5
—
7,3 ı 4,3
—
4,7 ı 2,9
—
—
20¹ – 52²
-20 – 35
A> -7 / 60²
47
46
2500
25
650 ı 1300 ı 1650
— ı —
0,42 ı 900
55
•
--
290
R1“AG
R1“AG
R407C ı 2,95
570 x 570
30 ı 1
3~/PE/400V/50Hz ı C10
1~/N/PE/230V/50Hz ı B10
3~/N/PE/400V/50Hz ı C10
1,65 ı 3,65 ı 0,66
5,7
32 ı 19
20
6 ı 4 ı 2
0,09 ı n.n.
• ı —
•
—
—
•
• ı 18 ı 1,5
•
•
813089a
Model designation
Heat pump type
Brine/water ı Air/water ı Water/water
• applicable ı — not applicable
Installation location
Indoors ı Outdoors
• applicable ı — not applicable
Conformity
CE
Performance data
Heating capacity/COP at
A7/W35
Standard point acc. to EN14511
2 condensers
1 condensers
kW ı …
kW ı …
A7/W45
Standard point acc. to EN14511
2 condensers
1 condensers
kW ı …
kW ı …
A2/W35
Operating point according to
EN14511
2 condensers
1 condensers
kW ı …
kW ı …
A10/W35
Operating point according to
EN14511
2 condensers
1 condensers
kW ı …
kW ı …
A-7/W35
Operating point according to
EN14511
2 condensers
1 condensers
kW ı …
kW ı …
A-15/W65
2 condensers
1 condensers
kW ı …
kW ı …
Limits of application
Heating circuit
°C
Heat source
°C
Additional operating points
…
Sound
Internal sound pressure level (open air test field, distance of 1m around the engine, average)
dB(A)
External sound pressure level (open air test field, distance of 1m around the air supplies, average) (2x 1m original straight air duct)
dB(A)
Heat source
Air volume flow at maximum external compression
m³/h
Maximum external pressure
Pa
Heating circuit
Volume flow: minimum flow rate ı nominal flow rate A7/W35 EN14511 ı maximum flow rate
l/h
Pressure loss heat pump ∆p ı volume flow
bar ı l/h
Free compression heat pump ∆p ı volume flow
bar ı l/h
Content of buffer tank
l
3-way valve, heating/hot water
…
General unit data
Dimensions (see dimensional drawing for the specified unit size)
unit size
Total weight
kg
Connections
Heating circuit
…
load circuit for domestic hot water
…
Refrigerant
Refrigerant type ı Quantity
… ı kg
Free cross section, air channels
mm
Cross section, condensate water ı length from unit
mm ı m
Electric
Voltage code ı all-pole circuit breaker heat pump **)
… ı A
Voltage code ı circuit breaker control voltage **)
… ı A
Voltage code ı circuit breaker electric heating element **)
ı A
Heat Pump
Effective power consumption in standard point A7/W35 acc. to EN14511: Power consumption ı current consumption ı cosφ
kW ı A ı …
Maximum device current within the limits of application
A
Starting current: direct ı with soft starter
A ı A
Protection type
IP
Output electric heating element 3 ı 2 ı 1 phase
kW ı kW ı kW
Components
Circulating pump heating circuit at nominal flow rate: Power consumption ı current consumption
kW ı A
Safety equipment
Safety component heating circuit ı Safety component heat source
Includ. in sc. of del.: • yes — no
Heating and heat pump regulator
Includ. in scope of delivery: • yes — no
Control and sensor wire
Includ. in scope of delivery: • yes — no
Power cable to unit
Includ. in scope of delivery: • yes — no
Electronic soft starter
integrated: • yes — no
Expansion vessels
Heat source: Scope of delivery ı Volume ı Initial pressure
• yes — no ı l ı bar
Overflow valve
integrated: • yes — no
Vibration decouplers
Heating circuit ı heat source
Included in scope of delivery: • yes — no
UK813085a
*) depending on components tolerances and flow **) comply with local regulations n.n. = not detectable w.w. = to choice
¹) hot water return ²) hot water flow
We reserve the right to modify technical specifications without prior notice.