9
We reserve the right to modify technical specifications without prior notice.
UK830504/210627
© Alpha-InnoTec GmbH
installation loCation
CautIon.
Install the unit only indoors.
The installation area must be frost-free and dry. It must
meet the requirements of dIN eN 378. It must also fulfill
applicable local regulations.
dimensional drawing and installation plan for
respective model.
transport to installation loCation
Always comply with the following safety information
during transport:
Danger!
several people are required to transport
the unit. Do not underestimate the weight
of the unit.
overview “Technical data / scope of delivery”,
“General unit data” section.
Danger!
the unit can tip when being removed from
the wooden pallet and during transport.
this can result in personal injury and
damage to the unit.
– take suitable precautionary measures
to eliminate the danger of tipping.
Danger!
Make sure to secure unit against slipping
during transport.
CautIon.
never use components and hydraulic
connections on the unit for purposes of
transport.
CautIon.
Do not damage the hydraulic connections
under any circumstances.
CautIon.
Do not tilt the unit more than a maximum
of 45° (in any direction).
To avoid damage during transport, you should transport
the unit to the final installation location in its original
packaging (with packaging on the wooden pallet), using
a lifting truck.
If it is not possible to transport the unit to the final
installation location using a lifting truck, you can also
transport the heat pump using a hand truck.
transport with a hand truCk
In order to reduce the weight of the unit for additional
transportation, we recommend using a hand truck to
remove the lower side walls and the lower front wall
prior to moving.
proceed as follows:
Remove packaging and set extra box aside (will be
needed later on!)…
lift unit from pallet.
Remove lower side panels and bottom front panel
of the unit…
•
To do so, loosen the quick-release screws. Turn
counter-clockwise 90°.
Содержание LWC 100
Страница 56: ......