7
HM 6Split
HM 12Split
Supplied components
Installation location
Removing the cover
Safety group with safe-
ty valve (3 bar), pressure
gauge and automatic air
vent (1 pc.)
Current sensor (3 pcs)
230V connection
jumper (1 pc.)
Hanger (1 szt.)
CAUTION
The rated opening pressure of the safety valve is 3
bar.
LEK
LEK
LEK
Section 2 |
Delivery and handling
Outdoor
temperature sensor
(1 pc.)
Indoor
temperature sensor
(1 pc.)
• Hanger (1 pc.)
• Safety group (1 pc.)
• Outdoor temperature sensor (1 pc.)
• Indoor temperature sensor (1 pc.)
• Current sensor (3 pcs)
• 230V connection jumper (1 pc.)
• Temperature sensor BT (3 pcs)
• Instalation and user manual
HM 6Split / HM 12Split can be installed in any room
protected against temperature drop below 0°C to
avoid freezing of the heating medium. 800 mm of
free space should be ensured in the front of the in-
door unit. All servicing of HM 6Split / HM 12Split can
be performed from the front.
1. Unscrew the bolts from the lower edge of the
front cover
1
.
2. Tilt the cover at the edge, making sure that the
connection cables are not damaged and discon-
nect the cable grounding the front cover
2
.
3. Disassemble the front cover by tilting its lower
edge toward you
3
and lifting it up
4
.
Min. 30 cm
Min. 20 cm
Min. 20 cm
CAUTION
Upon re-assembling the housing, the earthing wire
must be connected.
Temperature
sensor BT
(3 pcs)
4
3