Lift from the pallet to final posi
-
tioning
Scrapping
Indoor drain
Recommended alternative for
leading off condensation water
Condensation water drain
Condensation drains out on to the ground below L
Split. To avoid damage to the house and heat pump,
the condensation must be gathered and drained
away.
The condensation water is discharged to an indoor
drain (subject to local rules and regulations).
Route the pipe downward from the air/water heat
pump.
The condensation water drainage pipe must have a
water seal to prevent air circulation in the pipe.
• Condensate (50 l / 24 hours) is drained off via the
hose to the appropriate drain. It is recommended
that the route outside for the condensate is as
short as possible.
• The section of the pipe that may be affected by
frost must be heated by the heating cable to pre-
vent freezing.
• Route the pipe downward from the L Split heat
pump.
• The outlet of the condensation pipe must be at
a depth that is frost-free or, alternatively, indoors
(subject to local rules and regulations).
• Use a siphon for installations where air circula-
tion may occur in the condensation water drain-
age pipe.
• The insulation must be tightly fitted to the bot-
tom of the condensation water trough.
In case of scrapping, the product is dismantled by
performing the above actions in reverse order. Lift by
the bottom panel instead of a pallet!
Before lifting, remove the packaging and the strap se-
curing the product to the pallet.
Place lifting straps around each foot of the appliance.
Lifting from the pallet to the base requires four per-
sons, one for each lifting strap.
It is not permitted to lift the appliance by anything
other than the feet
CAUTION
Condensation drainage is important for the operation of
the heat pump. The condensation drain must be routed
such that it cannot damage the building.
CAUTION
The electrical installation and wiring must be carried out
under the supervision of an authorised electrician.
CAUTION
Do not connect heating cables with automatic adjust-
ment.
Water seal
Joint
LEK
Frostfritt
Frost proof
depth
Joint
Siphon
Ground