Section 9 |
Control
Mark “search installed slaves" and press the OK but-
ton to automatically find connected slaves for the
master heat pump.
Enter how your system is docked regarding pipes, for
example to pool heating, hot water heating and heat-
ing the building.
This menu has a docking memory which means that
the control system remembers how a particular re-
versing valve is docked and automatically enters the
correct docking the next time you use the same re-
versing valve.
Make different system settings for your installation
here, e.g. activate connected slaves and which ac-
cessories are installed.
If a slave is connected to the master installation, set
it here.
There are two ways of activating connected slaves.
You can either mark the alternative in the list or use
the automatic function "search installed slaves".
Set whether the compressor in the heat pump should
work to a particular curve under specific requirements
or if it should work to predefined curves.
You set a curve for a demand (heat, hot water etc.) by
unticking "auto", turning the control knob until a tem-
perature is marked and pressing OK. You can now set
at what temperatures the max. and min. frequencies,
respectively will occur.
This menu can consist of several windows (one for
each available demand), use the navigation arrows in
the top left corner to change between the windows.
Menu 5.2 - system settings
Menu 5.2.2 - installed slaves
Menu 5.2.3 - docking
Menu 5.1.23 - compressor curve
NOTE
This menu is only displayed if the controller is connect-
ed to a heat pump with inverter controlled compressor.
search installed slaves
This menu contains several sub-menus, one for each
standard.
Menu 5.1.22 - heat pump testing
NOTE
This menu is intended for testing the controller accord-
ing to different standards. Use of this menu for other
reasons may result in your installation not functioning as
intended.
CAUTION
The compressor curves can only be edited by qualified
personnel.
Factory setting:
Slave:
Here you select for which heat pump the dock-
ing setting is to be made.
Compressor:
Select if the compressor in the heat
pump is blocked, or standard (docked for example
to pool heating, hot water charging and heating the
building).
Marking frame:
Move around the marking frame us-
ing the control knob. Use the OK button to select
what you want to change and to confirm setting in
the options box that appears to the right.
Workspace for docking:
The system docking is drawn
here.
Slave (heat pump)
Workspace for docking
Compressor
Marking frame
CAUTION
Changing the factory range will result in incorrect op-
eration of the device.
Symbol
Description
Compressor (blocked)
Compressor (standard)
Reversing valves for hot water, cooling re-
spectively pool control.
The designations above the reversing valve
indicate where it is electrically connected
(EB101 = Slave 1, CL11 = Pool 1 etc.).
Hot water charging