background image

Model LPX1000 

c.p. Allstar Corporation 
Downingtown, PA  19335 
World Wide Web   [email protected]

This Gate Operator is built in the USA and 
complies with all requirements of 
Underwriters' Laboratories Standard UL-325.   
P/N 111785          Rev. D         November 2006

 

PHYSICAL 

 

PAD: 

18-1/4” W x 18-1/4”D x 3”H Elevation 

OVERHEAD CLEARANCE: 

Minimum 25” Required 

UNIT SIZE: 

15”W x 19”D x 24-1/4” H 

FRAME: 

Welded, Uni-Body; Phosphatized And 
Painted to UL Standards 

COVER: 

Architecturally Designed, Rust Free 
LLPE; Key Lock To Prevent 
Unauthorized Access 

SHIPPING WEIGHT: 

115 lbs. 

PRIMARY VOLTAGE: 

115 VAC, 60 Hz, Single Phase 

ELECTRICAL SOURCE: 

One 3-Wire, 15-Amp Service From 
Breaker Panel Required Per Operator 

CONTROL VOLTAGE: 

5 VDC 

RADIO RECEIVER POWER: 

24 VAC, 20 mA 

MOTOR: 

1/2 HP, 4.4 Amp, PSC, Instant Revers-
ing, Thermally Protected (Manual Reset) 

AUTO TIMER-TO-CLOSE: 

Built-In, Adjustable From 2-60 Seconds 

ELECTRICAL 

 

DRIVE 

 

DRIVE SYSTEM: 

Gearbox; 10:1; With Bronze Worm & 
Pinion Gears 

TOTAL SPEED REDUCTION: 

22.2:1 

OUTPUT SHAFT: 

1” dia., Ball-Bearing Mounted 

DRIVE MECHANISM: 

18-Tooth Sprocket; #41 Roller Chain 
30-Tooth Sprocket; #41 Roller Chain 
  High Speed Option, Class III & IV 

LIMITS: 

Independent Open & Close; Displaced 
Cam With Micro-Switch Contacts; 
Adjustable Without Tools 

OPERATOR LOCK: 

Electro-Mechanical, AC Solenoid; 
Engages On Close Limit, Drops Out If 
Power Is Interrupted 

MAX. GATE WEIGHT: 

1,300 lbs., Level Grade 

MAX. GATE WIDTH: 

35 ft.  Maximum Standard 
50 ft. Maximum High Speed Option 
   Class III & IV 

MAX. CYCLES PER HOUR: 

45 Open/Close Per Hour; 800 Open/
Close Per Day (All Calculations Based 
On Typical 20’ Gate On Level Grade) 

GATE SPEED: 

11.8 inches/second 
18 inches/second for High Speed 
   Option (Class III and IV) 

CAPACITIES 

 

Specifications subject to change without notice.  Consult the factory. 

Manufacturer’s Limited Warranty

 

The manufacturer warrants its gate operators to be free from defect in material and workmanship for a period of five (5) years from the date 
of purchase for single family home use and three (3) years from the date of purchase for multi-family and commercial use.  This warranty 
covers all components except the electronic circuit boards which are warranted for three (3) years from the date of purchase for single family 
home use and two (2) years from the date of purchase for multi-family and commercial use.  To obtain service contact your dealer.  

To obtain service under this warranty the buyer must obtain authorization instructions for the return of any goods from the manufacturer 
before returning the goods.  The goods must be returned with complete identification, with copy of proof-of-purchase, freight prepaid and in 
accordance with the manufacturer’s instructions or they will not be accepted.  In no event will the manufacturer be responsible for goods 
returned without proper authorization or identification. 

Goods returned to the manufacturer for warranty repair within the warranty period, which upon receipt by the manufacturer are confirmed to 
be defective and covered by this limited warranty, will be repaired or replaced at the manufacturer’s sole option, at no cost and returned pre-
paid.  Defective parts will be repaired or replaced with new or factory rebuilt parts at the manufacturer’s sole option. 

This limited warranty does not cover non-defect damage, damage caused by unreasonable use, damage caused by improper installation or 
care, vandalism or lightning, fire or excessive heat, flood or other acts of God (including, but not limited to misuse, abuse or alterations, 
failure to provide reasonable and necessary maintenance), labor charges for dismantling or reinstalling a repaired or replaced unit, or 
replacement batteries. 

These warranties are in lieu of all other warranties, either expressed or implied.  All implied warranties of merchantability and/or fitness for a 
particular purpose are hereby disclaimed and excluded.  Under no circumstances shall the manufacturer be liable for consequential, incidental 
or special damages arising in connection with the use or inability to use this product.  In no event shall the manufacturer’s liability for breach 
of warranty, breach of contract, negligence or strict liability exceed the cost of the product covered hereby.  No person is authorized to 
assume for the manufacturer any other liability in connection with the sale of this product. 

This warranty gives you specific legal rights.  You may also have other rights which vary from state to state.  Warranty effective after 
October 1, 2003. 

All questions and claims related to the manufacturer’s warranty should be directed to c.p. Allstar Corporation; 443 Boot Road; 
Downingtown, PA  19335; USA (telephone 610-873-6900).

 

 

  TECHNICAL SPECIFICATIONS  

24 

Содержание LEADER PLUS LPX1000 Series

Страница 1: ...ehicular gate operators READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS Serial Date Installed Your Dealer PROVEN CGA2K TECHNOLOGY INSTALLATION AND OWNER S MANUAL LEADER P...

Страница 2: ...ou and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instructions to avoid the hazard CAUTION Indicates a ME...

Страница 3: ...00 control panel provides independent connections for Open and Close non contact photoelectric and contact edge sensors In this way a photoelectric sensor could be utilized to guard the gate area when...

Страница 4: ...CAN BE MINIMIZED BY INSTALLING A MESH SCREEN ON THE GATE It is strongly recommended that the entire gate and adjacent fence area the gate covers when open be meshed or guarded such that a handhold or...

Страница 5: ...RED POWER LIGHT IS NOT LIGHTED HIGH VOLTAGE AC IS STILL PRESENT NEVER LEAVE THE INSTALLATION WITH THE HANDY BOX OR OUTER COVERS REMOVED ALWAYS TURN OFF THE POWER BEFORE ATTEMPTING SERVICE OF EITHER T...

Страница 6: ...ng adjustment to prevent one operator from overloading the other The electrical hookup is made in the junction box located in the left front corner of the frame see Figure 7 Page 7 For conduit placeme...

Страница 7: ...o one detector See Figure 8 above Two different types of installations will usually be encountered 1 If the driveway material is already in place saw cuts will be needed to accommodate the loop wires...

Страница 8: ...INSULATED WIRE WIRE SIZE SHOULD BE 16zGA STRANDED OR LARGER C INSTALLING THE OPERATOR TOOLS REQUIRED The following tools and materials are required for proper installation of the operator 1 Two 3 4 wr...

Страница 9: ...purpose Run flexible conduit from the point where the conduit exits the pad and attach it to the bottom of the right junction box at the front of the frame Review Figure 5 Page 6 If the hook up exits...

Страница 10: ...e operator side wall The actual loop is installed in the concrete or asphalt surface in accordance with the manufacturer s instructions and the information outlined earlier in this manual see Page 7 C...

Страница 11: ...now complete Connect one of the two wires for the relay to terminal 4 RADIO OPEN or terminal 3 ALTERNATE depending on the function desired see descriptions on the chart on page 17 and 18 and the othe...

Страница 12: ...nd facing outwards if the operator is on the right side of the gate it s a right hand installation If the operator is on the left side of the gate it s a left hand installation The operator is shipped...

Страница 13: ...lug it into the connector labeled LEFT HAND Locate the 3 position limit switch wire harness connector midway down on the right side of the controller board Switch it to the position labeled LEFT HAND...

Страница 14: ...nuous signal required to move the gate when in the alarm mode SWITCH 1 ON Gate does not respond to pushbutton input when in the normal mode Continuous signal required to move the gate when in the alar...

Страница 15: ...he Motor Close light stays ON 7 Connect to Terminal 11 Reversing Loop Observe that both Motor lights are ON momentarily and then the Motor Close light goes OUT and the Motor Open light stays ON 8 Conn...

Страница 16: ...re the power to the operator Restart the gate and give the leading edge a firm blow with the heal of your palm Don t stand directly in the gate s path while testing the Overload Force The obstruction...

Страница 17: ...nal for most HOLD OPEN functions Direct input to control system independent of the Loop Sockets Once activated the gate will open fully Activation while the gate is closing will cause it to re open Co...

Страница 18: ...ld be connected here and to terminals 16 COMMON Multiple devices may be connected in parallel NAME DESCRIPTION 12 OPEN EDGE Momentary or continuous signal This input is active only when referenced to...

Страница 19: ...IO OPEN ALTERNATE 16 15 13 14 12 9 10 7 8 5 6 3 4 2 1 24 VAC 24 VAC YEL YEL YEL YEL SOLENOID OPEN LIMIT RH CLOSED LIMIT RH WHT YEL RED LIMIT WIRE CONNECTIONS WHT COM COMMON RED YEL NO TRANSFORMER YEL...

Страница 20: ...and observe that the REVERSING LOOP light comes ON the operator control board and the gate reopens 2 FREE EXIT VEHICLE DETECTOR Pre test Test the vehicle detector independently using the presence lamp...

Страница 21: ...e or other need to move the gate manually without disconnecting the operator chain Take off the operator cover by first removing any lock attached to the lock tab on the operator front then lift the c...

Страница 22: ...ers for exposed rollers Each safety feature is a separate component in your gate system Read and follow all instructions for each of the components of your unique system Ensure that all instructions f...

Страница 23: ...hanical problems on the gate and gate hardware before installing the gate operator Have a qualified service technician make repairs to the gate and gate hardware AVOID ENTRAPMENT Stay away from the pa...

Страница 24: ...from the date of purchase for multi family and commercial use To obtain service contact your dealer To obtain service under this warranty the buyer must obtain authorization instructions for the retu...