2. CONNECTIONS
Front view
Side View
D1
M1
R
E
ME
IL
PL
F2
F4
F3
F1
M3
M2
M1
Board details
M1
Terminal block 1
M2
Terminal block 2
M3
Terminal block 3
P1
Button 1
P2
Button 2
P3
Button 3
D1
Dip switches inputs N.C.
disabling
R
Radio receiver connector
ME
Extractable memory
IL
Input led
PL
Power supply led
E
Encoder (optional)
F1
Fuse 1, Line 230Vac
F2
Fuse 2, inputs
F3
Fuse 3, photocells
F4
Fuse 4, auxiliaries 24V
1-2
ACCESSORIES OUTPUT 24Vac 10W.
3-4-5
PHOTOCELLS POWER SUPPLY
Connect the clamp 3 of the control unit to the clamp + of the
power supply of the photocells receiver.
Connect the clamp 4 of the control unit to the power supply
clamp - of the photocells receiver and of the transmitter.
Connect the clamp 5 of the control unit to the power supply
clamp of the trasnmitter of the photocells
The photocells test test is activated by the MENU A.
ATTENTION: the control unit gives a voltage of 24 Vdc and can
supply a maximum power of 5W.
For the safety edges test connect the test device of the safety
edge on the power supply pins of the TX (test activated wiht low
logic signal 0Vdc).
Please refer to the manual of the safety edge.
6-15
SAFETY EDGE INPUT
Connect the contact NORMALLY CLOSED of the SAFETY EDGE
between the clamps 6 and 15 of the terminal board.
ATTENTION: jumper the inputs if not used
The safety edge mode of opearation can be modified in the
MENU A.
7-15
PHOTOCELL INPUT
Connect the NORMALLY CLOSED contact of the photocell
(PHOTO) between the clamps 7 and 15 of the terminal board.
ATTENTION: jumper the inputs if not used
The functioning of the photocells can be modified in the MENU
A
8-15
INPUT CLOSING LIMIT SWITCH
Connect the contact NORMALLY CLOSED of the CLOSING LIMIT
SWITCH (L.S.CL.) between the clamps 8 and 15 of the control
board
Before activating the installation make sure that the limit
switches are functioning and correctly cabled
9-15
IINPUT OPENING LIMIT SWITCH
Connect the contact NORMALLY CLOSED of the OPENING LIMIT
SWITCH (L.S.CL.) between the clamps 9 and 15 of the terminal
board.
Before activating the installation make sure that the limit
switches are functioning and correctly cabled
10-15
STOP INPUT
Connect the contact NORMALLY CLOSED of the STOP between
the clamps 10 and 15 of the terminal board.
ATTENTION: Move the DIP STOP on ON position if not used
Содержание INVERTER COMPACT
Страница 1: ...INSTRUCTION INVERTER COMPACT FOR SLIDING GATES 6 1622616 R0 10 11 2017...
Страница 2: ...6 1622616 R0 06 10 2017 2 20...
Страница 3: ...6 1622616 R0 06 10 2017 3 20...
Страница 18: ...6 1622616 R0 06 10 2017 18 20 NOTE...
Страница 19: ...6 1622616 R0 06 10 2017 19 20...
Страница 20: ...6 1622616 R0 06 10 2017 20 20...