High Speed CL

OK

NNNHz

Regulation of the normal speed of the gate during the closing phase
speed expressed in Hz (frequency of the wave supplied to the motor)

Low Speed CL

OK

NNNHz

Regulation of the speed of the gate during the closing phase when approaching 
the end of the run
speed expressed in Hz (frequency of the wave supplied to the motor)

High Torque OP

OK

NNN%

Torque supplied to the motor during the opening phase at normal speed
percentage of torque supplied to the motor (000%...100%)

Low Torque OP

OK

NNN%

Torque supplied to the motor during the opening phase when approaching the 
end of the run
NNN: percentage of torque supplied to the motor (000%...100%)

High Torque CL

OK

NNN%

Torque supplied to the motor during the closing phase at normal speed
percentage of torque supplied to the motor(000%...100%).

Low Torque CL

OK

NNN%

Torque supplied to the motor during the closing phase when approaching the 
end of the run
percentage of torque supplied to the motor (000%...100%).

EXIT

OK

4.5 Programming menu C (key P3) -  List of parameters

The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted; refer to paragraphs dedicated to 
each function for more information

MENÙ C

Display

Language

OK

Select the language (where applicable)

Backlight

OK

OFF

ON

Backlighting of the display
the light of the display is disabled
the light of the display is enabled and its automatic switching-off is timed 
(Energy saving)

Reset

OK

Total reset of factory settings of the control board.
WARNING: all programming operations and the setting of the control board must 
be repeated after this operation

EXIT

OK

Содержание INVERTER COMPACT

Страница 1: ...INSTRUCTION INVERTER COMPACT FOR SLIDING GATES 6 1622616 R0 10 11 2017...

Страница 2: ...6 1622616 R0 06 10 2017 2 20...

Страница 3: ...6 1622616 R0 06 10 2017 3 20...

Страница 4: ...e installed the electric limit switches and to correctly adjusted them Note To use the obstacle detection function a compatible encoder must be installed first Fuses Fuses features F1 Protection line...

Страница 5: ...of the TX test activated wiht low logic signal 0Vdc Please refer to the manual of the safety edge 6 15 SAFETY EDGE INPUT Connect the contact NORMALLY CLOSED of the SAFETY EDGE between the clamps 6 an...

Страница 6: ...devices are correctly cabled and functioning refer to the preliminary checkings WARNING Risk of electric shock 19 20 COURTESY LIGHT Connect the courtesy light to the clamps 19 and 20 230Vac 100W MAX...

Страница 7: ...cessories 1 M1 3 3 3 3 3 Photo 24V Rx 0V 24V Tx M1 NC1 COM 6 15 NC 1 COM M1 PHOTO COM 7 15 PHOTO COM M1 LSC COM 8 15 LSC COM Closing Limit Switch M1 LSO COM 9 15 LSO COM Opening Limit Switch M1 STOP C...

Страница 8: ...PROGRAMMING 4 1 Activation and selection of the programming menu The INVERTER COMPACT control unit it is equipped with 3 user menu MENU A MENU B MENU C with which you can adjust program and modify all...

Страница 9: ...nual Motion OK MENU A P1 button allows activating the optional functions and selecting the intervention modes of the security systems MENU B P2 button it is dedi cated to learning the stroke to manual...

Страница 10: ...menu item see the following chart by shortly pressing the P3 button to skip to the next item or the P1 button to return to the previous one The display shows the selected menu item 4 Confirm the selec...

Страница 11: ...D allow only the opening of the gate disabled enabled WARNING enable the Automatic Re Closure in order to close Photo Inv OK OFF ON Photocell intervention modality the gate stays still until the obsta...

Страница 12: ...P2 List of parameters The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted refer to paragraphs dedicated to each function for more inf...

Страница 13: ...e motor during the closing phase at normal speed percentage of torque supplied to the motor 000 100 Low Torque CL OK NNN Torque supplied to the motor during the closing phase when approaching the end...

Страница 14: ...ts to move Watch its sense of rotation If the gate opens then stop the manual motion disconnect the system from the power and reverse the motor connections Then try again If the gate closes then stop...

Страница 15: ...g the pedestrian run allows to define the position of partial opening that allows the pedestrians accessing PED command Check that the adjustment of the torque and the speed of the gate are set before...

Страница 16: ...8 10 Edge Test Functional test of the safety edge Connect the safety edge as shown in the instructions by using the photocell test s clamp 8 11 Area light Possibility to use the auxiliary light outpu...

Страница 17: ...racting the movement The gate moves slowly despite having set an high speed Raise the torque supplied to the motor until problem is solved Low Torque OP Low Torque CL Lower the speed of the motor unti...

Страница 18: ...6 1622616 R0 06 10 2017 18 20 NOTE...

Страница 19: ...6 1622616 R0 06 10 2017 19 20...

Страница 20: ...6 1622616 R0 06 10 2017 20 20...

Отзывы: