background image

6-1622616 /R0 06/10/2017

10 / 20

To select the menu item, move with P1 and P3 keys, then press P2 to access the menu item.

AutoReclosingTim

OK

PhotoAutoReclose

OK

Brake

OK

           

To increase or decrease the value, move with P1 and P3, then press P2 to confirm

[OFF]

OK

+

-

001

OK

+

-

           

Wait for saving data set

SAVE

1. Stop the motor and get in safety conditions, The display must not show any indications. Press and keep pressed key P1 for 2 seconds in order to 
activate MENU A, The display shows the first entry available 
2. To activate the desired menu, press and hold for 2 seconds the appropriate button.
Once accessed the desired menu (A, B, C), you can scroll it with the P1 and P3 buttons, you can access the desired item (enter) with P2 (central 
button) and you can confirm the desired parameter (saving).
3. Select the desired menu item (see the following chart) by shortly pressing the P3 button to skip to the next item or the P1 button to return to the 
previous one. The display shows the selected menu item.
4. Confirm the selection of the item by pressing the P2 button.
5. Change the parameter status by following the indications on the second line of the display, using the P1 and P3 button. The first line of the display 
indicates the current setting for the selected function. The second line shows the possible modification according to the selected parameter (see the 
specific paragraphs).
6. Confirm the setting by pressing the P2 button. The display indicates the saving followed by the selected menu item.
7. It is possible to modify further menu items (go back to point 3) or exit the programming menu by selecting EXIT (confirm with P2 button). The exit is 
confirmed by the absence of any indication on the display.

AUTOMATIC EXIT FROM MENU: in case of extended inactivity (15 seconds) the menu will be automatically disabled.

Содержание INVERTER COMPACT

Страница 1: ...INSTRUCTION INVERTER COMPACT FOR SLIDING GATES 6 1622616 R0 10 11 2017...

Страница 2: ...6 1622616 R0 06 10 2017 2 20...

Страница 3: ...6 1622616 R0 06 10 2017 3 20...

Страница 4: ...e installed the electric limit switches and to correctly adjusted them Note To use the obstacle detection function a compatible encoder must be installed first Fuses Fuses features F1 Protection line...

Страница 5: ...of the TX test activated wiht low logic signal 0Vdc Please refer to the manual of the safety edge 6 15 SAFETY EDGE INPUT Connect the contact NORMALLY CLOSED of the SAFETY EDGE between the clamps 6 an...

Страница 6: ...devices are correctly cabled and functioning refer to the preliminary checkings WARNING Risk of electric shock 19 20 COURTESY LIGHT Connect the courtesy light to the clamps 19 and 20 230Vac 100W MAX...

Страница 7: ...cessories 1 M1 3 3 3 3 3 Photo 24V Rx 0V 24V Tx M1 NC1 COM 6 15 NC 1 COM M1 PHOTO COM 7 15 PHOTO COM M1 LSC COM 8 15 LSC COM Closing Limit Switch M1 LSO COM 9 15 LSO COM Opening Limit Switch M1 STOP C...

Страница 8: ...PROGRAMMING 4 1 Activation and selection of the programming menu The INVERTER COMPACT control unit it is equipped with 3 user menu MENU A MENU B MENU C with which you can adjust program and modify all...

Страница 9: ...nual Motion OK MENU A P1 button allows activating the optional functions and selecting the intervention modes of the security systems MENU B P2 button it is dedi cated to learning the stroke to manual...

Страница 10: ...menu item see the following chart by shortly pressing the P3 button to skip to the next item or the P1 button to return to the previous one The display shows the selected menu item 4 Confirm the selec...

Страница 11: ...D allow only the opening of the gate disabled enabled WARNING enable the Automatic Re Closure in order to close Photo Inv OK OFF ON Photocell intervention modality the gate stays still until the obsta...

Страница 12: ...P2 List of parameters The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted refer to paragraphs dedicated to each function for more inf...

Страница 13: ...e motor during the closing phase at normal speed percentage of torque supplied to the motor 000 100 Low Torque CL OK NNN Torque supplied to the motor during the closing phase when approaching the end...

Страница 14: ...ts to move Watch its sense of rotation If the gate opens then stop the manual motion disconnect the system from the power and reverse the motor connections Then try again If the gate closes then stop...

Страница 15: ...g the pedestrian run allows to define the position of partial opening that allows the pedestrians accessing PED command Check that the adjustment of the torque and the speed of the gate are set before...

Страница 16: ...8 10 Edge Test Functional test of the safety edge Connect the safety edge as shown in the instructions by using the photocell test s clamp 8 11 Area light Possibility to use the auxiliary light outpu...

Страница 17: ...racting the movement The gate moves slowly despite having set an high speed Raise the torque supplied to the motor until problem is solved Low Torque OP Low Torque CL Lower the speed of the motor unti...

Страница 18: ...6 1622616 R0 06 10 2017 18 20 NOTE...

Страница 19: ...6 1622616 R0 06 10 2017 19 20...

Страница 20: ...6 1622616 R0 06 10 2017 20 20...

Отзывы: