background image

6-1622616 /R0 06/10/2017

15 / 20

WARNING: the photocells and the safety edge are not monitored during this phase! 

WARNING! 

during this phase the photocells and the coast are not monitored! Access the manual movement item of MENU B and confirm by pressing 

the P2 key. Move the gate using the P1 and P3 keys. To exit the menu, press the P2 button or wait for 15 seconds.

7. LEARNING

Learning the run of the gate (Menu B - Final position). Learning the run allows to define the parameters of the run of the gate, such as the width of the 
run at normal speed and at slowed speed. Check that the adjustment of the torque and the speed of the gate are set before carrying out the learning 
phase. Check that the gate is closed before starting the learning phase.

End Position

OK

LEARN OP

EXIT

START

MENU’ B, end position

allows you to start learning the 
races, starting from the opening 
movement. Access the item

Press and release the 
START key (P1), the gate 
will start to open.

SLOW

When the gate has reached 
the position where you want 
to start the slowing down 
phase, press the RALL button 
(P1)

LEARN OP

EXIT

The gate continues at reduced 
speed until the opening limit 
switch is reached. When the 
limit switch is reached, it auto-
matically restarts in closing

LEARN OP

EXIT

LEARN CL

EXIT

SLOW

When the gate has 
reached the position where 
you want to start the 
slowing down phase, press 
the RALL button (P1)

LEARN CL

EXIT

When the closing limit 
switch is reached, the 
learning is performed.

7.1 Learning the partial opening phase (Menu B –  Ped. Position). Make sure that the electric limit switches are assembled and 

properly adjusted.

Learning the pedestrian run allows to define the position of partial opening that allows the pedestrians accessing (PED command)
Check that the adjustment of the torque and the speed of the gate are set before carrying out the learning phase. Check that the gate is closed before 
starting the learning phase.
Enter the parameter Ped. Position of MENU B and confirm by pressing key P2. Start moving the gate by pressing and releasing key P1 (START) or a 
Step-by-Step key. When the gate reaches the position of pedestrian opening, then push key P1 (START) or a step-by-step key
The gate moves again in closing. When the gate hits the limit in closing, then the programming is terminated. Exit the menu by scrolling the entries 
until you find EXIT

7.2 Adjustment of the speed and the torque (Menu B -  Speed and torque)

The entries of menu B - Speed and torque - once the parameters themselves are entered allow to adjust the corresponding parameters from a 
minimum up to a maximum value, according to the indications shown on the display. The versatility of the control board allows an infinity of possible 
combinations: however it is recommended  to adjust the settings by keeping into account the dimensions and weight of the gate. High speeds may be 
dangerous, as well as high torques. Such regulations must be carried out only by professionals. It is recommended to check the correct functioning of 
the automation after any regulation. It is highly recommended to learn the runs of the gate each time these parameters are changed.

8. ADVANCED FUNCTIONS

These are functions  and/or functional modalities that can be activated by the user through the programming menu.

8.1 AUTOMATIC RECLOSURE

 

Timed closing of the gate from totally open position or pedestrian opening position. The “stop” command disables the automatic closing until a new 

Содержание INVERTER COMPACT

Страница 1: ...INSTRUCTION INVERTER COMPACT FOR SLIDING GATES 6 1622616 R0 10 11 2017...

Страница 2: ...6 1622616 R0 06 10 2017 2 20...

Страница 3: ...6 1622616 R0 06 10 2017 3 20...

Страница 4: ...e installed the electric limit switches and to correctly adjusted them Note To use the obstacle detection function a compatible encoder must be installed first Fuses Fuses features F1 Protection line...

Страница 5: ...of the TX test activated wiht low logic signal 0Vdc Please refer to the manual of the safety edge 6 15 SAFETY EDGE INPUT Connect the contact NORMALLY CLOSED of the SAFETY EDGE between the clamps 6 an...

Страница 6: ...devices are correctly cabled and functioning refer to the preliminary checkings WARNING Risk of electric shock 19 20 COURTESY LIGHT Connect the courtesy light to the clamps 19 and 20 230Vac 100W MAX...

Страница 7: ...cessories 1 M1 3 3 3 3 3 Photo 24V Rx 0V 24V Tx M1 NC1 COM 6 15 NC 1 COM M1 PHOTO COM 7 15 PHOTO COM M1 LSC COM 8 15 LSC COM Closing Limit Switch M1 LSO COM 9 15 LSO COM Opening Limit Switch M1 STOP C...

Страница 8: ...PROGRAMMING 4 1 Activation and selection of the programming menu The INVERTER COMPACT control unit it is equipped with 3 user menu MENU A MENU B MENU C with which you can adjust program and modify all...

Страница 9: ...nual Motion OK MENU A P1 button allows activating the optional functions and selecting the intervention modes of the security systems MENU B P2 button it is dedi cated to learning the stroke to manual...

Страница 10: ...menu item see the following chart by shortly pressing the P3 button to skip to the next item or the P1 button to return to the previous one The display shows the selected menu item 4 Confirm the selec...

Страница 11: ...D allow only the opening of the gate disabled enabled WARNING enable the Automatic Re Closure in order to close Photo Inv OK OFF ON Photocell intervention modality the gate stays still until the obsta...

Страница 12: ...P2 List of parameters The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted refer to paragraphs dedicated to each function for more inf...

Страница 13: ...e motor during the closing phase at normal speed percentage of torque supplied to the motor 000 100 Low Torque CL OK NNN Torque supplied to the motor during the closing phase when approaching the end...

Страница 14: ...ts to move Watch its sense of rotation If the gate opens then stop the manual motion disconnect the system from the power and reverse the motor connections Then try again If the gate closes then stop...

Страница 15: ...g the pedestrian run allows to define the position of partial opening that allows the pedestrians accessing PED command Check that the adjustment of the torque and the speed of the gate are set before...

Страница 16: ...8 10 Edge Test Functional test of the safety edge Connect the safety edge as shown in the instructions by using the photocell test s clamp 8 11 Area light Possibility to use the auxiliary light outpu...

Страница 17: ...racting the movement The gate moves slowly despite having set an high speed Raise the torque supplied to the motor until problem is solved Low Torque OP Low Torque CL Lower the speed of the motor unti...

Страница 18: ...6 1622616 R0 06 10 2017 18 20 NOTE...

Страница 19: ...6 1622616 R0 06 10 2017 19 20...

Страница 20: ...6 1622616 R0 06 10 2017 20 20...