Periodic Inspection
62
Insulation resistance should be regularly checked or measured with a 500V insulation resistance meter.
If it is reduced to lower than 1MΩ, it could cause an electrical leakage or a fire.
For recovery or improvement of insulation resistance, wipe and clean dust and dirt around output
terminals, circuit breaker, generator body outlet port and receptacle and dry them. If it insulation
resistance does not recover after cleaning, contact your distributor.
After making sure that the insulation resistance of
the generator is higher than 1 MΩ, be sure to
re-connect the cable between the terminal [N] and terminal [Ground] just as it was originally connected. If
it is left disconnected, the grounding becomes imperfect so that it could cause electric shock.
Check Thermo Label on the Generator
Every 2 months or 250 Hours
Thermo-label on the rotor bearing irreversibly changes its color from white to blue by reaching or exceeding
176°F (
80°C
)
. Be sure to check the bearing for abnormal noise and vibration if it has changed color.
<Procedure>
Replace thermo-label if it has changed color.
When replacing, contact our office or distributor.
Drain Fuel Tank
Every 250 Hours
<Procedure>
To drain fuel tank, remove drain plug [B], and open
drain valve [C] to drain the condensate accumulated in
fuel tank [A].
After making sure that all condensate is completely
drained out, close drain valve [C] firmly and install drain
plug [B].
Dispose of condensate according to the designated
regulations.
A
B D
C
Thermo Label
Содержание Maxi-Power MP65 T4F
Страница 65: ...N o t f o r R e p r o d u c t i o n 65 Dimensions units in...
Страница 66: ...N o t f o r R e p r o d u c t i o n 66 ALLMAND COM Dimensions units mm...
Страница 67: ...N o t f o r R e p r o d u c t i o n 67 Generator Wiring Diagram...
Страница 68: ...N o t f o r R e p r o d u c t i o n 68 ALLMAND COM Engine Wiring Diagram...
Страница 69: ...N o t f o r R e p r o d u c t i o n 69 Connector Terminal Arrangement...
Страница 71: ...N o t f o r R e p r o d u c t i o n 71 7 Specifications 7 2 Cooling Water Piping A180829E Engine...
Страница 74: ...N o t f o r R e p r o d u c t i o n 74 ALLMAND COM...
Страница 75: ...N o t f o r R e p r o d u c t i o n 75...
Страница 76: ...N o t f o r R e p r o d u c t i o n...