Allmand Maxi-Power MP65 T4F Скачать руководство пользователя страница 1

Not for 

Reproduction

Copyright © 2019 Allmand Bros., Inc.
Holdrege, NE, USA. All rights reserved.

116128

Revision A

Operator’s Manual

Maxi-Power

Towable Generator

Model MP65 T4F

en

Содержание Maxi-Power MP65 T4F

Страница 1: ...N o t f o r R e p r o d u c t i o n Copyright 2019 Allmand Bros Inc Holdrege NE USA All rights reserved 116128 Revision A Operator s Manual Maxi Power Towable Generator Model MP65 T4F en...

Страница 2: ...ns thoroughly before attempting to start or operate this equipment Save these original instructions for future reference Where to Find Us If you have any questions about the machine contact your autho...

Страница 3: ...t i o n 3 Table of Contents Operator Safety 4 Features and Controls 10 Transporting and Set Up 12 Operation 15 Maintenance 41 Storage 58 Troubleshooting 59 Specifications 63 Operation Log 72 Addendum...

Страница 4: ...if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert agai...

Страница 5: ...nformation for you A plate stamped with the model and serial number is attached to back side of the machine A040491 Each illustrated figure Fig has a number for instance A040491 at the right bottom Th...

Страница 6: ...ediately place an order with your nearest dealer for replacement Part numbers are indicated on the lower right corner of the label Adhere a new one to the original location 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 7: ...p r o d u c t i o n 7 Safety 7 The locations of the safety warning labels are as follows 14 13 12 1 2 A 11 10 9 8 7 6 3 4 5 B P O A B C D E F H I J K L M N G O R P Q Trailer Labels Unit Labels Q R 21...

Страница 8: ...plate which is displayed in the manual or on the machine carefully understand its content and follow the indications thereof Do not modify the machine without prior approval The safety may be compromi...

Страница 9: ...lated inside control panel could cause malfunction or difficulties with the instruments Clean them using compressed air A100285 Waste liquid from the machine contains harmful material Do not discharge...

Страница 10: ...ing device for filtering dust floating in intake air E Voltage Selector Switch For switching output voltage F Control Panel For controlling device various meters and controls G Alternator For generati...

Страница 11: ...t gas temperature during manual cleaning D Reserve Tank For checking coolant level and supplying it E Radiator For cooling the coolant for engine in the system F DEF Tank Container for DEF G DOC Diese...

Страница 12: ...njury or death Proper tire air pressure Tire lug nuts are not loose Tires are not worn or damaged Ensure that the end of the drawbar is securely connected to the coupler of the towing vehicle Ensure t...

Страница 13: ...is a simplified three phase three wire formula to seek voltage drop or cross sectional area of the cable from cable length and working current Select such a cable length and thickness so that the volt...

Страница 14: ...es set as shown A When operating the unit using installed fuel tank run the machine with the fuel line piping and selector valves with the factory arranged settings 2 When using a separate storage tan...

Страница 15: ...N o t f o r R e p r o d u c t i o n 15 Operation Operation 23 Control Panel A B F E D C A Panel Light B Controller C Circuit Breaker D Panel Light Switch E Voltage Adjuster F Control Power Switch...

Страница 16: ...utton 2 Parameters within an item can be viewed by pressing and button 3 Monitor will return to main screen if no commands are entered for 3 minutes Main Screen Status Engine Generator Alarms ECU Curr...

Страница 17: ...ctly by the circuit breaker of the generator It could cause damage to the circuit breaker Connect the connecting cable to the load so that the output terminals should not touch each other When removin...

Страница 18: ...ot operate the voltage selector switch Voltage selection during operation may cause abnormal voltage on the load side to damage the load and may cause a fire In addition it could cause damage to gener...

Страница 19: ...e voltage selector switch is turned to 240 120V on the control panel Procedure 1 Turn the voltage selector switch to 240 120V on the control panel when the generator unit stops 2 Start the generator u...

Страница 20: ...Values shown in the left column give the maximum current available at the 120V 20A GFCI receptacles compared to the value of the simultaneous current consumption from the main terminals Allowable load...

Страница 21: ...he outside air temperature Ambient temperature range and oil viscosity SAE A180818E Do not mix oils If two or more different brands of oil are mixed its performance can be deteriorated When it is expe...

Страница 22: ...of its mixing ratio between 30 and 60 If LLC antifreeze exceeds more than 60 it may decrease its antifreezing effect Mixing ratio of LLC antifreeze reference Outside temperature F 5 4 13 22 31 40 49 O...

Страница 23: ...f DEF is not within specification contact the DEF supplier for assistance with disposal Do not dump substantial quantities of DEF onto the ground or send DEF to wastewater treatment facilities Avoid c...

Страница 24: ...efore the checking oil level When you check oil level after you have started operation wait more than 10 minutes after stopping the engine before checking the oil level Procedures 1 Pull out the engin...

Страница 25: ...nt within the radiator and surge tank A010012 Opening the radiator cap while hot could result in severe burns Do not open the radiator cap while hot When removing the radiator cap lightly turn it and...

Страница 26: ...to the fuel The fuel is extremely flammable and dangerous Be careful of fire because the fuel is very likely to catch fire Refuel only after stopping the engine and never leave open fuel can near the...

Страница 27: ...ing Pop up REFILL DEF REFILL DEF REFILL DEF NO POWER Monitor Lamp Warning ON ON ON Check Interior Periodically check the inside of the generator for dust and flammables Please wear personal protective...

Страница 28: ...ening the alternator mounting bolts and nuts While pressing the center of the belt slightly adjust belt tension by loosening fitting bolt so the amount of deflection is between 6 6 and 7 4 mm at 98 Ne...

Страница 29: ...il fence drain port is located at the front of the machine A180562 Remove drain plug A from the oil fence drain to drain the condensate Check that all condensate is drained and then re install the dra...

Страница 30: ...o run the engine Preheating is started automatically in cold weather After the GLOW lamp E is off the engine starts 5 Once engine has started let it warm up approximately 5 minutes at no load conditio...

Страница 31: ...r approx 5 minutes Warming up after starting up is necessary for smooth operation of the engine Do not operate the engine at full load immediately after it starts up This will shorten the equipment li...

Страница 32: ...starts automatically After glow lamp E is switched off the engine starts 5 Setting remote control terminals A1 A2 to OFF stops the engine Inspection and maintenance prohibited during automatic operat...

Страница 33: ...engine will not start after cranking for 10 seconds stop it for 8 seconds before trying again If the engine will not start even after cranking is repeated three times the SHUTDOWN lamp I will illumin...

Страница 34: ...reen Be sure to frequently check meters and indicators for proper operation or any machine water oil fuel leaks etc The above table gives standard values They may vary slightly depending on operating...

Страница 35: ...n using 1 phase load check the current of each phase and try to keep the load of each phase constantly average If you continue to operate the generator while ignoring or neglecting these cautions it c...

Страница 36: ...ement C and loosen the priming pump E push the priming pump E back and forth until fuel comes out more than 20 times 5 After air removal is completed tighten the air release plug D and push the primin...

Страница 37: ...be stop immediately Cancellation of emergency stop button Turn it to allow right direction to unlock A15461 1 After emergency stopping be sure to carry out an investigation of the problem which cause...

Страница 38: ...leaning During SCR system cleaning there may be white smoke or ammonia smell generated temporary This is normal Do not operate the unit in area where ventilation is insufficient Make sure to install v...

Страница 39: ...is required to restore operation In case of emergency it is possible to operate the unit for 30 minutes by performing escape mode Monitor Display during SCR Inducement State Detect 3 0 Hr From Detect...

Страница 40: ...the tick button to edit Inactive begins to flash press the up arrow to change to Active press the tick to confirm Active ceases to flash 5 Press and hold the tick button to return to main screen 6 St...

Страница 41: ...der Inspection label to an easy to see location Remove the negative side cable from the battery If the above procedure is neglected and another person starts operating the machine during check or main...

Страница 42: ...uel Check fuel pre filter drain Check DEF Check belt tension Replace belt as needed Change engine oil Change engine oil filter Check battery Check Clean air filter element Check exhaust system Drain w...

Страница 43: ...month and of 1 500 hours of use per year Periodic Replacement Parts Part number changes upon modification For replacement of parts make sure whether the part number is correct or applicable Descripti...

Страница 44: ...in oil 2 After draining is completed close the drain valve B install the drain plug A and then supply engine oil Oil supply about 4 14 gal 15 7L 3 Make sure to check engine oil level with the dipstick...

Страница 45: ...250 hours Specific gravity of battery electrolyte every 500 hours If there to be a problem in starting an engine due to a flat battery carry out the checks by following the procedures below Ordinary...

Страница 46: ...way with a large amount of water immediately If the battery electrolytes get into your eyes flush them immediately with plenty of water and see a doctor at once Severe damage to eyes and vision may re...

Страница 47: ...will cause sparking and damage to each component Check and Clean Air Filter Elements Every 250 Hours When the air filter monitor lamp glows clean the air filter Procedure 1 After removing the cap A by...

Страница 48: ...standard value Frequency Hz 60 Rated voltage V 240 480 Load current A 120 60 In case of load operation increase load factor step by step while checking the condition of the exhaust Do not place flamma...

Страница 49: ...3 Remove the AVR connector A inside the generator control panel 4 Remove connector B at the rear side of the control panel 5 Switch ON circuit breaker C measure each insulation resistance between the...

Страница 50: ...l Ground just as it was originally connected If it is left disconnected the grounding becomes imperfect so that it could cause electric shock Check Thermo Label on the Generator Every 2 months or 250...

Страница 51: ...to remove the filter case C 3 Replace the O ring with new one and place new element D in the case Thinly apply the fuel on the O ring and screw in the element 4 After the O ring contacts seal surface...

Страница 52: ...side may spill out Turn the cap A to the counterclockwise to remove and clean filter B inside Replace the gasket C whenever the filter A is removed Check and Cleaning of the Supply pump strainer Every...

Страница 53: ...s to check on the generator side Terminal connection of 3 phase output terminal plate Main circuit of circuit breaker Terminal connection on control box Each terminal connection of each instrument Ite...

Страница 54: ...ase E by hand and make sure that the hooks of the cap fixing latches B are securely attached and tightened The air filter is an important part and is crucial to machine s performance and life Be sure...

Страница 55: ...ce it with a new one Check each hose clamp and if any loose hoses are found retighten them Even before the maintenance interval comes replace hoses if hardening cracks or fissures are found When repla...

Страница 56: ...ly new coolant from the filler port of radiator D 4 After changing the coolant run the engine under unload operation for 2 to 3 minutes then stop it Check the coolant level again and replenish it if n...

Страница 57: ...nce Grease Trailer Hub Bearing Contact your authorized dealer Check Wheel Lug Nuts Tire Pressure Check tightness of wheel lug nuts C Tighten to 90 100 lb ft 122 136 Nm Also check tire pressure Adjust...

Страница 58: ...ery month 4 Discharge coolant and fuel from the machine 5 Seal air intake port of engine and other openings like the muffler with a vinyl sheet packing tape etc to prevent moisture and dust from getti...

Страница 59: ...kPa High Coolant Temp ON ON ECU Red Water Temp High Shutdown above 212 F 100 C Over speed ON ON ECU Red Engine Speed High Shutdown above 2070rpm Clogging Air Filter ON Air Filter When it is clogged or...

Страница 60: ...lace Circuit protector CP for AVR protection AVR is equipped with a circuit protector CP for protection against over current It will activate under the following conditions The machine is overloaded w...

Страница 61: ...arter rotates normally but engine does not start up 1 No diesel fuel oil 2 Air mixing in fuel piping 3 Fuel filter clogging 4 Nozzle clogging 5 Malfunction of controller Replenish fuel Bleed air Disas...

Страница 62: ...ing of generator main machine 8 Faulty silicon rectifier mounted on generator main machine rotor 9 Faulty voltmeter Check tightening Check select Repair Repair Reset Change Repair Change Change Too hi...

Страница 63: ...el ISUZU BR 4JJ1XAGD 03 Type 4 Cycle water cooled direct injection Turbocharged EGR Aftertreatment DOC SCR No of Cylinders 4 Displacement gal liters 2 999 Output hp kW 62 4 Engine Speed min 1 1 800 Lu...

Страница 64: ...ions including trailer Tire Size 205 75R15 Axle Type Tandem Torsion Trailer Brake Type Hydraulic Surge Dry Weight lbs kg 4 445 2016 Operating Weight lbs kg 5 170 2345 Length in mm 157 3988 Width in mm...

Страница 65: ...N o t f o r R e p r o d u c t i o n 65 Dimensions units in...

Страница 66: ...N o t f o r R e p r o d u c t i o n 66 ALLMAND COM Dimensions units mm...

Страница 67: ...N o t f o r R e p r o d u c t i o n 67 Generator Wiring Diagram...

Страница 68: ...N o t f o r R e p r o d u c t i o n 68 ALLMAND COM Engine Wiring Diagram...

Страница 69: ...N o t f o r R e p r o d u c t i o n 69 Connector Terminal Arrangement...

Страница 70: ...ND COM 7 Specifications 7 1 Piping System Diagram Fuel Piping DEF Piping A180782 A180783E Engine Internal Fuel Tank External Fuel Tank Fuel Return Fuel Selector Valve Fuel Outlet Fuel Inlet Fuel Suppl...

Страница 71: ...N o t f o r R e p r o d u c t i o n 71 7 Specifications 7 2 Cooling Water Piping A180829E Engine...

Страница 72: ...U STOP TIME START TIME OUTPUT VOLTAGE V TOTAL OPERATION HOURS h AMBIENT TEMP F FREQUENCY Hz OPERATION LOG REMARKS INSPECTION PART CHANGE HISTORY ETC OUTPUT CURRNT A ENG OIL REPLACEMENT HOUR h ENG OIL...

Страница 73: ...eater should be used whenever the unit is not in use in temperatures below 32 F 0 C 1 Plug the female end of a heavy duty power cord not supplied into the Block Heater Battery Heater recessed receptac...

Страница 74: ...N o t f o r R e p r o d u c t i o n 74 ALLMAND COM...

Страница 75: ...N o t f o r R e p r o d u c t i o n 75...

Страница 76: ...N o t f o r R e p r o d u c t i o n...

Отзывы: