Allied Construction Products, LLC www.alliedcp.com
27
TM102783_BreakerLube CML_15jul
7.0 Maintenance – [cont’d]
7.3 How to Re-fill the Reservoir
WARNING
Electric shock hazard. Shut off power
to BreakerLube before servicing.
CAUTION
Crush / entanglement hazard. Keep
hands clear of moving parts. Shut off
power to BreakerLube before
servicing.
CAUTION
Follow correct procedures to prevent the formation of
air pockets. Air pockets disrupt the flow of grease to
bushings and tool and are time-consuming to purge.
The low level control is triggered when the grease
level has reached the intermediate plate. Stop and
re-fill the reservoir through the grease nipple located
on the front of pump housing.
CAUTION
Contamination interferes with reliable operation and
will shorten pump life. Prevent contaminants from
entering when re-filling. Do not re-fill by removing
the reservoir lid. Store unused portions of Chisel
Paste in a clean dry area. Do not use grease that
has change consistency over time.
Fig. 7-2 Unapproved Re-fill Method
The recommended method for refilling the reservoir is
thru the grease nipple located on the front of the
pump housing.
1. Use a hand operated grease gun (manual lever
or power type). Wipe debris from grease nipple.
Attach the grease gun to lubrication nipple on the
front of the pump housing.
Fig. 7-3 Reservoir Re-fill Location Identified
CAUTION
The reservoir may burst if overfilled. DO NOT
exceed the ‘MAX’ fill mark. Blocking the vent can
affect grease flow.
7.4 Daily Walk Around Inspection
Check the grease level in reservoir. Re-fill as
necessary.
Check for leaks in system. Tighten connections
that are loose.
Replace kinked, crushed or worn hoses.
Check relief valve at pump element for signs of
grease discharge. If buildup is observed, locate
restriction and make necessary corrections.
Fig. 7-4 Delivery Adjustment – OK
- Lacking X -
Excessive X
DO NOT REFILL HERE
-MIN-